24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor.

نویسندگان

  • Benjamin Mottet
  • Florent Aptel
  • Jean-Paul Romanet
  • Ralitsa Hubanova
  • Jean-Louis Pépin
  • Christophe Chiquet
چکیده

IMPORTANCE This study evaluates a new device that has been proposed to continuously monitor intraocular pressure (IOP) over 24 hours. OBJECTIVE To evaluate 24-hour IOP rhythm reproducibility during repeated continuous 24-hour IOP monitoring with noncontact tonometry (NCT) and a contact lens sensor (CLS) in healthy participants. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional study of 12 young healthy volunteers at a referral center of chronobiology. INTERVENTIONS Participants were housed in a sleep laboratory and underwent four 24-hour sessions of IOP measurements over a 6-month period. After initial randomized attribution, the IOP of the first eye was continuously monitored using a CLS and the IOP of the fellow eye was measured hourly using NCT. Two sessions with NCT measurements in 1 eye and CLS measurements in the fellow eye, 1 session with CLS measurements in only 1 eye, and 1 session with NCT measurements in both eyes were performed. MAIN OUTCOMES AND MEASURES A nonlinear least squares, dual-harmonic regression analysis was used to model the 24-hour IOP rhythm. Comparison of acrophase, bathyphase, amplitude, midline estimating statistic of rhythm, IOP values, IOP changes, and agreement were evaluated in the 3 tonometry methods. RESULTS A significant nyctohemeral IOP rhythm was found in 31 of 36 sessions (86%) using NCT and in all sessions (100%) using CLS. Hourly awakening during NCT IOP measurements did not significantly change the mean phases of the 24-hour IOP pattern evaluated using CLS in the contralateral eye. Throughout the sessions, intraclass correlation coefficients of the CLS acrophase (0.6 [95% CI, 0.0 to 0.9]; P = .03), CLS bathyphase (0.7 [95% CI, 0.1 to 0.9]; P = .01), NCT amplitude (0.7 [95% CI, 0.1 to 0.9]; P = .01), and NCT midline estimating statistic of rhythm (0.9 [95% CI, 0.9 to 1.0]; P < .01) were significant. When performing NCT measurements in 1 eye and CLS measurements in the contralateral eye, the IOP change at each point normalized from the first measurement (9 am) was not symmetric individually or within the population. CONCLUSIONS AND RELEVANCE The CLS is an accurate and reproducible method to characterize the nyctohemeral IOP rhythm in healthy participants but does not allow for estimating the IOP value in millimeters of mercury corresponding to the relative variation of the electrical signal measured.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.

PURPOSE To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. PATIENTS AND METHODS Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sen...

متن کامل

Hourly awakening vs continuous contact lens sensor measurements of 24-hour intraocular pressure: effect on sleep macrostructure and intraocular pressure rhythm.

IMPORTANCE All studies of 24-hour intraocular pressure (IOP) rhythm conducted to date have used repeated IOP measurements requiring nocturnal awakenings, potentially disturbing sleep macrostructure. OBJECTIVE To evaluate the effects on sleep architecture and IOP rhythm of hourly awakening vs a contact lens sensor (CLS) to continuously monitor IOP without awakening. DESIGN, SETTING, AND PART...

متن کامل

The Fluctuation of Intraocular Pressure Measured by a Contact Lens Sensor in Normal-Tension Glaucoma Patients and Nonglaucoma Subjects.

PURPOSE We compared the fluctuation of intraocular pressure (IOP) in normal-tension glaucoma (NTG) patients and individuals with nonglaucoma eyes. We obtained continuous IOP values using a SENSIMED Triggerfish contact lens sensor. MATERIALS AND METHODS The eyes of 12 nonglaucoma subjects and 14 NTG patients were examined. In all 26 subjects, the IOP fluctuation was measured continuously for 2...

متن کامل

Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma.

OBJECTIVE To examine the safety, tolerability, and reproducibility of intraocular pressure (IOP) patterns during repeated continuous 24-hour IOP monitoring with a contact lens sensor. METHODS Forty patients suspected of having glaucoma(n=21) or with established glaucoma (n=19) were studied.Patients participated in two 24-hour IOP monitoring sessions (S1 and S2) at a 1-week interval (SENSIMED ...

متن کامل

Twenty-four-hour intraocular pressure patterns in a symptomatic patient after ab interno trabeculotomy surgery

We report the results of repeated ambulatory continuous 24-hour intraocular pressure (IOP) monitoring with a contact lens sensor (CLS) in a glaucoma patient with ocular pain after ab interno trabeculotomy (Trabectome™) surgery. Our findings show that a combined prostaglandin-pilocarpine treatment reduced nighttime IOP peaks and relieved the patient's symptoms.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 131 12  شماره 

صفحات  -

تاریخ انتشار 2013