A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index.

نویسندگان

  • Katharine H Fraser
  • Tao Zhang
  • M Ertan Taskin
  • Bartley P Griffith
  • Zhongjun J Wu
چکیده

Ventricular assist devices (VADs) have already helped many patients with heart failure but have the potential to assist more patients if current problems with blood damage (hemolysis, platelet activation, thrombosis and emboli, and destruction of the von Willebrand factor (vWf)) can be eliminated. A step towards this goal is better understanding of the relationships between shear stress, exposure time, and blood damage and, from there, the development of numerical models for the different types of blood damage to enable the design of improved VADs. In this study, computational fluid dynamics (CFD) was used to calculate the hemodynamics in three clinical VADs and two investigational VADs and the shear stress, residence time, and hemolysis were investigated. A new scalar transport model for hemolysis was developed. The results were compared with in vitro measurements of the pressure head in each VAD and the hemolysis index in two VADs. A comparative analysis of the blood damage related fluid dynamic parameters and hemolysis index was performed among the VADs. Compared to the centrifugal VADs, the axial VADs had: higher mean scalar shear stress (sss); a wider range of sss, with larger maxima and larger percentage volumes at both low and high sss; and longer residence times at very high sss. The hemolysis predictions were in agreement with the experiments and showed that the axial VADs had a higher hemolysis index. The increased hemolysis in axial VADs compared to centrifugal VADs is a direct result of their higher shear stresses and longer residence times. Since platelet activation and destruction of the vWf also require high shear stresses, the flow conditions inside axial VADs are likely to result in more of these types of blood damage compared with centrifugal VADs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A tensor-based measure for estimating blood damage.

Implantable ventricular assist devices give hope of a permanent clinical solution to heart failure. These devices, both pulsatile- and continuous-flow, are presently used as medium-term bridge to heart transplant or recovery. While long-term use of continuous-flow axial and centrifugal pumps is being explored, the excessive level of blood damage in these devices has emerged as a design challeng...

متن کامل

Laser Doppler Anemometry Study of the Flow in a Blood Filter

Damage to red blood cells can be induced chemically, by osmosis or mechanically. The fluid mechanical effect can be related to the device design, its surface characteristics and to the degree of flow disturbance or turbulence caused by the device. Is generally accepted that the presence of high turbulent shear stresses generated in the flow fields of artificial devices are partially responsible...

متن کامل

Hemolysis in a laminar flow-through Couette shearing device: an experimental study.

Reducing hemolysis has been one of the major goals of rotary blood pump development and in the investigational phase, the capability of hemolysis estimation for areas of elevated shear stresses is valuable. The degree of hemolysis is determined by the amplitude of shear stress and the exposure time, but to date, the exact hemolytic behavior at elevated shear stresses and potential thresholds fo...

متن کامل

Effects of Suspension Osmolarity on Rbc Mechanical Properties and Shear Induced Hemolysis

INTRODUCTION Storage of human red blood cells (RBCs) began around 1910 when the anticoagulant properties of citrate were discovered. Over the last century, RBC storage techniques were improved so patients can receive healthy RBCs after longer storage periods. Today, about 80 million transfusions per year are performed worldwide [1,2]. Many parameters, such as temperature and nutrient concentrat...

متن کامل

PIV measurements of flow in a centrifugal blood pump: steady flow.

Magnetically suspended left ventricular assist devices have only one moving part, the impeller. The impeller has absolutely no contact with any of the fixed parts, thus greatly reducing the regions of stagnant or high shear stress that surround a mechanical or fluid bearing. Measurements of the mean flow patterns as well as viscous and turbulent stresses were made in a shaft-driven prototype of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 134 8  شماره 

صفحات  -

تاریخ انتشار 2012