Reliability of an Integrated Ultrasound and Stereophotogrammetric System for Lower Limb Anatomical Characterisation

نویسندگان

  • Frederick Greatrex
  • Erica Montefiori
  • Thomas Grupp
  • Josef Kozak
  • Claudia Mazzà
چکیده

BACKGROUND Lower extremity analysis for preoperative total knee and hip arthroplasty routines can increase surgery success rate and hence reduce associated costs. Current tools are limited by being invasive, limited to supine analysis, or too expensive. This study aimed to propose and validate a device, OrthoPilot®, based on the combined use of a stereophotogrammetric and ultrasound system which can in vivo and noninvasively measure varus/valgus, flexion/extension, femur and tibia torsion, and femur and tibia lengths. METHODS A phantom was measured by four operators to determine the resolution of the system. Interoperator variability was measured on three operators who measured the above six variables on both legs of three subjects in standing and supine positions. Intraoperator variability was assessed on data from three repeats from 9 subjects (18 legs). RESULTS All 6 variables were reliably detected on a phantom, with a resolution of 1 mm and 0.5°. Inter- and intraoperator consistency was observed for varus/valgus, flexion/extension, and length measurements on the healthy subjects in standing and supine positions (all ICC > 0.93). For torsion measurements, there was a considerable variation. CONCLUSION The proposed system, when used on healthy subjects, allowed reliable measurements of key parameters for preoperative procedures in both supine and standing positions. Accuracy testing and further validation on patient populations will be the next step toward its clinical adoption.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perforator Flaps for Reconstruction of Lower Limb Defects

BACKGROUND Reconstruction of soft tissue defects in the lower third of the leg remains challenging. Anatomical constraints limit the local options available for complex defects especially lower third of leg. Local flaps based on perforator vessels are raising interest in reconstructive surgery of the limbs. We present our experience with perforator flaps for reconstruction of soft tissue def...

متن کامل

Reliability of Ultrasound Imaging of the Trunk Musculature in Athletes with and without Hamstring Injuries

Background: Trunk muscles play an important role in providing both mobility and stability during dynamic tasks in athletes.The purpose of this study was to evaluate the within-day and between-day reliability of ultrasound (US) in measuringabdominal and lumbar multifidus muscle (MF) thickness in athletes with and without hamstring strain injury (HSI).Methods: Fifteen male socce...

متن کامل

Position and orientation in space of bones during movement: anatomical frame definition and determination.

This paper deals with methodological problems related to the reconstruction of the position and orientation of the human pelvis and the lower limb bones in space during the execution of locomotion and physical exercises using a stereophotogrammetric system. The intention is to produce a means of quantitative description of joint kinematics and dynamics for both research and application. Anatomi...

متن کامل

Estimation of Stature from the Anthropometric Measurement of Lower Limb in Iranian Adults

Introduction: Estimation of stature is one of the most important fields in forensic medicine. Also it is of particular interest to anthropologists and anatomist. Our aim was to investigate the relationship between stature and the length of lower limb and foot to derive a regression formula for estimating the stature. Methods: Three anthropometric measurements Stature, Lower Limb Length (LL...

متن کامل

A Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)

This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017