Salt-dependent DNA superhelix diameter studied by small angle neutron scattering measurements and Monte Carlo simulations.

نویسندگان

  • M Hammermann
  • N Brun
  • K V Klenin
  • R May
  • K Tóth
  • J Langowski
چکیده

Using small angle neutron scattering we have measured the static form factor of two different superhelical DNAs, p1868 (1868 bp) and pUC18 (2686 bp), in dilute aqueous solution at salt concentrations between 0 and 1.5 M Na+ in 10 mM Tris at 0% and 100% D2O. For both DNA molecules, the theoretical static form factor was also calculated from an ensemble of Monte Carlo configurations generated by a previously described model. Simulated and measured form factors of both DNAs showed the same behavior between 10 and 100 mM salt concentration: An undulation in the scattering curve at a momentum transfer q = 0.5 nm-1 present at lower concentration disappears above 100 mM. The position of the undulation corresponds to a distance of approximately 10-20 nm. This indicated a change in the DNA superhelix diameter, as the undulation is not present in the scattering curve of the relaxed DNA. From the measured scattering curves of superhelical DNA we estimated the superhelix diameter as a function of Na+ concentration by a quantitative comparison with the scattering curve of relaxed DNA. The ratio of the scattering curves of superhelical and relaxed DNA is very similar to the form factor of a pair of point scatterers. We concluded that the distance of this pair corresponds to the interstrand separation in the superhelix. The computed superhelix diameter of 16.0 +/- 0.9 nm at 10 mM decreased to 9.0 +/- 0.7 nm at 100 mM salt concentration. Measured and simulated scattering curves agreed almost quantitatively, therefore we also calculated the superhelix diameter from the simulated conformations. It decreased from 18.0 +/- 1.5 nm at 10 mM to 9.4 +/- 1.5 nm at 100 mM salt concentration. This value did not significantly change to lower values at higher Na+ concentration, in agreement with results obtained by electron microscopy, scanning force microscopy imaging in aqueous solution, and recent MC simulations, but in contrast to the observation of a lateral collapse of the DNA superhelix as indicated by cryo-electron microscopy studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of crowding on the conformation of interwound DNA strands from neutron scattering measurements and Monte Carlo simulations.

With a view to determining the distance between the two opposing duplexes in supercoiled DNA, we have measured small angle neutron scattering from pHSG298 plasmid (2675 base pairs) dispersed in saline solutions. Experiments were carried out under full and zero average DNA neutron scattering contrast using hydrogenated plasmid and a 1:1 mixture of hydrogenated and perdeuterated plasmid, respecti...

متن کامل

Benchmark Experiment of Neutron Resonance Scattering Models in Monte Carlo Codes

Experimental measurements of elastic neutron scattering from U resonances were used to benchmark neutron scattering models in Monte Carlo transport codes. It was found that the implementation of the free gas model to determine the scattered neutron energy and angle in popular Monte Carlo codes is inaccurate. Differences up to a factor of two in the energy dependent angular distribution were obs...

متن کامل

Sea Surfaces Scattering by Multi-Order Small-Slope Approximation: a Monte-Carlo and Analytical Comparison

L-band electromagnetic scattering from two-dimensional random rough sea surfaces are calculated by first- and second-order Small-Slope Approximation (SSA1, 2) methods. Both analytical and numerical computations are utilized to calculate incoherent normalized radar cross-section (NRCS) in mono- and bi-static cases. For evaluating inverse Fourier transform, inverse fast Fourier transform (IFFT) i...

متن کامل

Monte Carlo simulations of the new small-angle neutron scattering instrument SANS-1 at the Heinz Maier-Leibnitz Forschungsneutronenquelle

A new small-angle scattering instrument SANS-1 will be installed on beamline NL 4a at the Heinz Maier-Leibnitz Forschungsneutronenquelle (FRM II). It is a joint venture between the Technische Universität München and the Geesthacht Neutron Facility (GENF). SANS-1 has been optimized to be one of the most intense and versatile small-angle scattering instruments within the boundaries of available s...

متن کامل

High-sensitivity Radioactive Xenon Monitoring and High-accuracy Neutron-proton Scattering Measurements

Johansson, C. 2004. High-sensitivity Radioactive Xenon Monitoring and High-accuracy Neutron-proton Scattering Measurements. Acta Universitatis Upsaliensis. Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 984. 59 pp. Uppsala. ISBN 91-554-5979-X Two aspects of applied nuclear physics have been studied in this thesis; Monte Carlo simulations for high-sen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biophysical journal

دوره 75 6  شماره 

صفحات  -

تاریخ انتشار 1998