Renal Scanning for Localization and Shielding of the Kidneys in Patients Candidate for Abdominal Radiotherapy
نویسنده
چکیده
Introduction: Clinical radiation nephropathy can result in considerable morbidity and/or mortality. Renal tolerance (TD5/5) has been stated to be 20 Gy when irradiation has been delivered to both kidneys in 3-5 weeks. Therefore to minimize renal toxicity in these patients, localization and shielding of the kidneys are essential. This study was carried out to evaluate the role of Tc-DTPA renal scintigraphy in renal localization for perfect shielding. Methods: From April 2000 to March 2001, thirteen patients had complete history, physical examination, serum creatinine level, complete blood count, urinalysis and abdominal sonography. Then the patients were referred to nuclear medicine department. After I.V. injection of 10 mCi TcDTPA, the kidneys were localized by gamma camera and marked on skin. All patients received abdominal radiation with A-P and P-A fields with cobalt 60 machine up to 3000-5000CGY. Kidneys were shielded posteriorly after 1500cGY with 5 HVL (Half value layer) blocks. Results: After minimum follow-up of 24 months, no evidence of increasing blood pressure, edema, proteinuria, rising in serum creatinin or changing in kidney size was found. Conclusion: The results show that localization of kidneys by Tc-DTPA is a useful, easy and safe method to shield kidneys in these patients.
منابع مشابه
Evaluation of 99mTc-DTPA renal scanning for localization and shielding of the kidneys in patients candidate for abdominal radiotherapy
Introduction: Clinical radiation nephropathy can result in considerable morbidity and/or mortality. Renal tolerance (TD5/5) has been stated to be 20 Gy when irradiation has been delivered to both kidneys in 3-5 weeks. Therefore to minimize renal toxicity in these patients, localization and shielding of the kidneys are essential. This study was carried out to evaluate the role of 99mTc-DTP...
متن کاملComparison of IVP-simulator and 99mTc-DMSA renal scaning for renal localization and shielding in candidates for radiation therapy [Persian]
To minimize renal radiation in abdomical radiotherapy, shielding of the kidneys is essential. IVP-simulator is used as an standard method. In this study, we used 99mTc-DMSA to localize and shield the Kidneys and we compared this method with IVP-simulator. The size of the kidneys was proven to be larger as compared with IVP method. The mean of the overlap percentage was 81.88 in right and ...
متن کاملبررسی دقت سیتیاسکن اسپیرال با بازسازی به روش Multi Planar(MPR) در اندازهگیری طول کلیه در بیمارستان شهید هاشمینژاد در سال 1383
Background & Aim: Measuring the length of kidneys is an important issue in diagnosis and treatment of renal diseases. In various diseases, kidneys become larger or smaller than normal. Ultrasonography is a suitable method for measuring renal length because it is accurate, noninvasive, available and with low cost. Nowadays, multislice spiral CT scanners are widely used for evaluation of rena...
متن کاملRENAL TRANSPLANTATION A BETTER QUALITY OF LIFE FOR UREMIC PATIENTS, REVIEW OF RESULTS IN 69 KIDNEY TRANSPLANTIONS
Between June, 1984 and January 20, 1987, 69 kidney transplantations were performed in our department. All kidneys were acquired from living donors. 63% of the cases were high-risk MLC-positive (poorly matched), and all but one were from related sources. There were only five rejected kidneys, all of which occurred in kidneys from parent donors. 28 recipients received donor-specific transfus...
متن کاملEvaluation of 58 cases of 99mTc-DTPA renal transplantation scans [Persian]
Nuclear medicine methods have important role in the evaluation of transplanted kidney. In this study 58 99mTc-DTPA scans were performed in 38 patients. This method has 90% sensitivity and 96% specificity. In the cases of normal transplanted kidneys, function correlation between doppler sonography and scanning was more than dysfunctioning kidneys.
متن کامل