Comparison of commercial kits for radioimmunoassay: III. Radioassay of serum folate.
نویسندگان
چکیده
We evaluated six commercial radioassay kits in which tritium or iodine tracers are used to measure serum folate. We assessed the adequacy of the literature supplied with the kits, within-run precision, reagent stability, analytical recovery of added pteroylglutamic acid and N-methyltetrahydrofolic acid, results of analysis of patients' samples, and minimum detection limits. There were serious discrepancies among manufacturers' kits in each of these respects. Such discrepancies could affect interpretation of results and of data on like samples derived from different laboratories that are using different kits. Laboratories are urged to assess carefully the materials and method supplied by a manufacturer before putting a kit to clinical use.
منابع مشابه
Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood.
We compared results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested...
متن کاملAnalytical evaluation of a folate radioassay: application to serum and erythrocyte measurements.
Many commercial folate radioassay kits have proven to be unsatisfactory in the past. It has been found that the Schwarz/Mann Iodine-125 folate radioassay kit permits a rapid measurement of folic acid requiring only a single incubation at pH 9.3. At this pH, the relative affinity of pteroylglutamic acid (FA) and N-5-methyltetrahydrofolic acid (MTFA) for the milk binder is the same. Additionally,...
متن کاملComparison of radioassay and microbiological assay for serum folate, with clinical assessment of discrepant results.
Folate assays by use of radiolabeled folate provide obvious practical advantages over the standard microbiological assay, but remain incompletely tested. We therefore compared results for 415 sera with a kit involving 3H-labeled folate and the Lactobacillus casei microbiological method. We examined the patients' data when there were discrepancies between the two methods. Although the correlatio...
متن کاملTwo radioassays for serum vitamin B12 and folate determination compared in a reference interval study.
For 154 subjects, we verified that vitamin B12 and folate status was normal, using as criteria the average polymorphonuclear lobe count, mean corpuscular volume, and hemoglobin concentration. We then used blood from these subjects to compare values obtained with two radioassay kits, each designed for simultaneous vitamin B12 and folate determination. Although regression analysis showed reasonab...
متن کاملDiscordant inter-kit results in the radioimmunoassay for choriogonadotropin in serum.
Discordant results for concentrations of choriogonadotropin (HCG) in sera from five of 162 women are reported, as determined with four commercial radioassay kits: Becton-Dickinson, Clinetics, Corning, and Hybritech. Results ranged from 11.2 to 36.7 int. units/L, when assayed with the Becton-Dickinson kit, but HCG was not detectable when assayed with the other kits. None of the patients was preg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 21 13 شماره
صفحات -
تاریخ انتشار 1975