Generation of a Recombinant Gag Virus-Like-Particle Panel for the Evaluation of p24 Antigen Detection by Diagnostic HIV Tests
نویسندگان
چکیده
BACKGROUND Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection. RESULTS Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection. CONCLUSIONS The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.
منابع مشابه
Cloning, Expression, Purification and Immunoreactivity Analysis of Gag Derived Protein p17 from HIV-1 CRF35 in Fusion with Thioredoxin from Human Subjects
So far, recombinant antigens of HIV-1, the etiologic cause of Acquired Immunodeficiency Syndrome (AIDS), have been widely used for the diagnosis and vaccine development. P17 or the matrix protein formed by the proteolytic cleavage of gag is strongly antigenic and is as conserved and immunogenic as p24. In some cases, antibodies to p17 are more prevalent than antibodies to p24 and the decline in...
متن کاملEvaluation of a New Anti-HIV1/2 ELISA–HIV 1/2 REC Diagnostic Kit Based on E. coli Derived Soluble Recombinant Proteins: Ex-perience of an International Study
Background/Objective: Development of a new enzyme-linked immunosorbent assay (ELISA) for screening human blood serum and plasma for antibodies to human immunodeficiency virus type 1 (HIV1) and type 2 (HIV2) as HIV1/2REC ELISA diagnostic kit based on E. coli derived soluble recombinant proteins. Methods: Polypeptides corresponding to HIV1 gp41 and HIV2 gp36 immunodominant regions and HIV1 gag we...
متن کاملImpact of naturally occurring amino acid variations on the detection of HIV-1 p24 in diagnostic antigen tests
BACKGROUND The detection of HIV-1 p24 antigen in diagnostic tests relies on antibodies binding to conserved areas of the protein to cover the full range of HIV-1 subtypes. Using a panel of 43 different virus-like particles (VLPs) expressing Gag from clinical HIV-1 isolates, we previously found that some highly sensitive tests completely failed to detect p24 of certain VLPs, seemingly unrelated ...
متن کاملEvaluation of HIV Indeterminate Confirmatory Tests\' Results in Blood Donors in Northeast of Iran
Background and Aims: Human Immunodeficiency virus (HIV) is spreading rapidly among the people worldwide. Infection with this virus leads to immune suppression and finally acquired immune deficiency syndrome. Early HIV detection is dependent on antibody screening against virus by Enzyme Linked Immunosorbent Assay (ELISA). Some confirmatory tests such as Western Blot and Recombinant Immunobl...
متن کامل-MicroRNAs: New biomarkers for diagnosing HIV-
According to the increasing number of AIDS patients and their deaths, Treatment is a very important debate to prevent this Which is dependent on early and Accurate diagnosis. Currently, there are different diagnostic methods, including virus cultures, rapid tests, western blot, and other tests for this infection. Among these, HIV RNA TESTING, especially APTIMA HIV RNA ASSAY and fourth generatio...
متن کامل