Quest for an efficient binary working mixture for an absorption-demixing heat transformer

نویسندگان

  • Romain Privat
  • Jun-Wei Qian
  • Dominique Alonso
  • Jean-Noël Jaubert
چکیده

The aim of the present paper is to identify a highly efficient binary mixture to be used in an absorptiondemixing heat transformer (ADHT) in order to make it more energy-efficient than the conventional absorption heat transformer (AHT). Firstly, 128 binary mixtures potentially interesting in terms of pure component boiling temperatures and upper critical solution temperature (UCST) were selected among thousands for which experimental information related to partial miscibility was available. Secondly, the parameters of the NRTL activity coefficient model were determined for each selected mixture, showing a good agreement between phase-equilibrium calculation and experimental data points. Hence, with the help of the reliable NRTL model, the performance evaluation of the ADHT cycle operating with various working pairs was carried out through the estimation of the internal temperature lift (DTi). Despite a large number of binary mixtures investigated, only 38 ones showed a positive DTi and the most significant value was about 5 K. Finally, in the light of the undertaken modeling work, it was possible to establish the characteristics of the best binary mixture usable in an ADHT. Consequently, a highly efficient binary mixture exhibiting a DTi value of 50 K for industrial application certainly does not exist, owing to the conflict among its characteristic requirements. 2013 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigations on the Thermal Performance of a Vertical Closed Loop Pulsating Heat Pipe Using Binary Mixture of Fluids

This paper presents the experimental investigations conducted on a vertical closed loop pulsating heat pipe (VCLPHP) to evaluate the thermal performance. The values of thermal resistance and heat transfer coefficient obtained in the experimentation is used as evaluation parameters. The VCLPHP used has capillary tubes having an inner diameter of 2mm and outside diameter 3mm and bent into 5 turns...

متن کامل

A Numerical Modeling of a Variable Conductance Thermosyphon by Use of a Binary Mixture

In this paper the steady state performance of a variable conductance heat pipe, which its working fluid consists of two components (R11+ R113) is modeled. The role of the liquid film momentum and axial normal stresses are considered by use of the mean property of mixture and the governing equations are solved by conventional numerical methods. The results of the present model have been compared...

متن کامل

Entropy-driven demixing in binary hard-core mixtures: From hard spherocylinders towards hard spheres

We present a computer simulation study of a binary mixture of hard spherocylinders with different diameters (D1,D2) and the same lengths (L15L25L). We first study a mixture of spherocylinders with lengths L 515D2 and D150, which can be regarded as a mixture of rodlike colloids and ideal needles. We find clearly an entropy-driven isotropic-isotropic (I-I) demixing transition in this mixture. In ...

متن کامل

Demixing behavior in two-dimensional mixtures of anisotropic hard bodies.

Scaled particle theory for a binary mixture of hard discorectangles and for a binary mixture of hard rectangles is used to predict possible liquid-crystal demixing scenarios in two dimensions. Through a bifurcation analysis from the isotropic phase, it is shown that isotropic-nematic demixing is possible in two-dimensional liquid-crystal mixtures composed of hard convex bodies. This bifurcation...

متن کامل

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

An investigation of heat recovery for power generation using an absorption-Rankine cycle with a low temperature waste heat source was conducted. In such a cycle, the condenser and boiler of a conventional Rankine system are replaced with an absorber and desorber. A recuperative solution heat exchanger is also incorporated between the absorber and desorber to minimize the external heat input. An...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016