Instantaneous Active and Reactive Power Measuring Method in Three Phase Power System

نویسندگان

  • A. TAHRI
  • A. DRAOU
  • Azeddine Draou
چکیده

This paper describes an electronic means of measuring the instantaneous active and reactive power absorbed by any electrical equipment. The measurements are based on the Clark (α-β) and Park (d-q) transformations. The system is useful to teach electrical machines in Park’s coordinates and it allows also the study and control of some power electronics converters that are connected to three phase power network, such as static VAR compensator. The principle of the measuring method of the active and reactive power is described, and analyzed for different tests. The effectiveness of the proposed measuring method is confirmed by experimental investigation employing a test system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

متن کامل

A Novel Method to Increase the Power Capacity of Transmission Lines Using Transformerless Static Synchronous Series Compensator

In this paper a transformerless Static Synchronous Series Compensator (SSSC) to increase the power capacity of a 230 kV transmission line is proposed. In order to eliminate the transformer, a 15-level cascade H Bridge (CHB) inverter is employed within the proposed compensator structure to inject reactive power to the transmission line. The theory of instantaneous p-q power using in the compensa...

متن کامل

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

A Grid-connected PV Power Supply based on Flying Capacitor multicell converter with modified MPPT based Control for Active Power Filtering

This paper presents a grid connected photovoltaic system, which acts as both power generator and active power filter (APF), based on Flying Capacitor Multicell (FCM) converter. Increase in the number of output voltage levels, natural self-balancing of flying capacitors and dc link voltage and lower power rating of components are the main futures of FCM converter compared with conventional multi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005