Verification of the patient positioning in the bellyboard pelvic radiotherapy.

نویسندگان

  • Mladen Kasabasić
  • Dario Faj
  • Djeni Smilović Radojcić
  • Manda Svabić
  • Ana Ivković
  • Slaven Jurković
چکیده

The size and shape of the treatment fields applied in radiotherapy account for uncertainties in the daily set-up of the patients during the treatment. We investigated the accuracy of daily patient positioning in the bellyboard pelvic radiotherapy in order to find out the magnitude of the patients movement during the treatment. Translational as well as rotational movements of the patients are explored. Film portal imaging is used in order to find patient positioning error during the treatment of the pelvic region. Patients are treated in the prone position using the bellyboard positioning device. Thirty six patients are included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisition was completed in 85% and systematic and random positioning errors in 453 images are analyzed. Translation of the patient during the treatment caused set-up errors that ranged up to 30 mm and rotation of the sacrum ranged up to 14 degrees. We found out that most of the patients had time trend (drift of the position or angle during the time). This is predominant in the first few days while patient accommodate to uncomfortable prone position in the bellyboard. Safety margins that will ensure 90% probability of depositing at least 95% of the prescribed dose in the target are calculated according to translational movement of the patient. No action level, off line, set-up protocol is employed to correct patient position because of the translational movement. To correct for the rotation of the patient anatomy, correction of the custom shielding blocks should be employed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms

Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...

متن کامل

Dosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance

Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...

متن کامل

Verification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry

Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...

متن کامل

EPID in vivo Dosimetry

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

متن کامل

Determination of geometric accuracy of radiotherapy fields by port film and DRR using Matlab Graphical User Interface

Introduction: Radiation therapy is one of the methods of cancer treatment. In this method, it is necessary to avoid harming the healthy tissues of the patient which is in the vicinity of the target, as much as possible. Treatment verification is one of the most important steps of radiation therapy which has two usual methods, using Port film and EPID. The accuracy and precision of treatment in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 32 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2008