A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.
نویسندگان
چکیده
Three dimensional bilateral imaging is the standard for most clinical breast dynamic contrast-enhanced (DCE) MRI protocols. Because of high spatial resolution (sRes) requirement, the typical 1-2 min temporal resolution (tRes) afforded by a conventional full-k-space-sampling gradient echo (GRE) sequence precludes meaningful and accurate pharmacokinetic analysis of DCE time-course data. The commercially available, GRE-based, k-space undersampling and data sharing TWIST (time-resolved angiography with stochastic trajectories) sequence was used in this study to perform DCE-MRI exams on thirty one patients (with 36 suspicious breast lesions) before their biopsies. The TWIST DCE-MRI was immediately followed by a single-frame conventional GRE acquisition. Blinded from each other, three radiologist readers assessed agreements in multiple lesion morphology categories between the last set of TWIST DCE images and the conventional GRE images. Fleiss' κ test was used to evaluate inter-reader agreement. The TWIST DCE time-course data were subjected to quantitative pharmacokinetic analyses. With a four-channel phased-array breast coil, the TWIST sequence produced DCE images with 20 s or less tRes and ~ 1.0×1.0×1.4 mm(3) sRes. There were no significant differences in signal-to-noise (P=.45) and contrast-to-noise (P=.51) ratios between the TWIST and conventional GRE images. The agreements in morphology evaluations between the two image sets were excellent with the intra-reader agreement ranging from 79% for mass margin to 100% for mammographic density and the inter-reader κ value ranging from 0.54 (P<.0001) for lesion size to 1.00 (P<.0001) for background parenchymal enhancement. Quantitative analyses of the DCE time-course data provided higher breast cancer diagnostic accuracy (91% specificity at 100% sensitivity) than the current clinical practice of morphology and qualitative kinetics assessments. The TWIST sequence may be used in clinical settings to acquire high spatiotemporal resolution breast DCE-MRI images for both precise lesion morphology characterization and accurate pharmacokinetic analysis.
منابع مشابه
Dynamic Contrast-Enhanced MRI of Mouse Liver: A Feasibility Study Using a Dual-Input Two-Compartment Tracer Kinetic Model
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been widely applied to evaluate microcirculatory parameters in clinical settings. However, pre-clinical studies involving DCE-MRI of small animals remain challenging with the requirement for high spatial and temporal resolution for quantitative tracer kinetic analysis. This study illustrates the feasibility of applying a high te...
متن کاملAutomatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملInitial Experience of Applying TWIST-Dixon With Flexible View Sharing in Breast DCE-MRI.
INTRODUCTION We developed a new fast imaging technique with flexible time-resolved angiography with stochastic trajectories (TWIST) view sharing to achieve variable temporal resolution and with flexible echo time Dixon to achieve robust fat suppression and to evaluate its application in breast dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI). MATERIALS AND METHODS The TWIST-Dixo...
متن کاملK-Space Acquisition Method for Dynamic Contrast-Enhanced MRI : Application to Breast Tumors
K-Space Acquisition Method for Dynamic Contrast-Enhanced MRI: Applicationto Breast Tumors bySumati Krishnan Chairs: Jeffrey A. Fessler and Thomas L. Chenevert Dynamic contrast-enhanced (DCE)-MRI is increasingly being used for detection anddiagnosis of tumors. The primary objective is to elicit diagnostically significantarchitectural and pharmacokinetic features of lesions. Hence...
متن کاملEvaluation of the reproducibility of a protocol for the pharmacokinetic study of breast tumors by dynamic magnetic resonance imaging.
OBJECTIVE To evaluate the reproducibility of a protocol for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the pharmacokinetic study of breast tumors. MATERIAL AND METHODS We carried out this prospective study from October 2009 through December 2009. We studied 12 patients with stage ii-iii invasive breast cancer without prior treatment. Our center's research ethics commit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 30 9 شماره
صفحات -