Canadian Trial of Physiological Pacing: Effects of physiological pacing during long-term follow-up.
نویسندگان
چکیده
BACKGROUND The Canadian Trial of Physiological Pacing (CTOPP) reported that the risk of stroke or cardiovascular death was similar between patients receiving ventricular versus physiological pacemakers at the end of the original follow-up period of 3 years. However, the occurrence of atrial fibrillation was significantly less frequent with physiological pacemakers. To assess a potential delayed benefit of physiological pacing, follow-up of patients in this study was extended to 6 years. METHODS AND RESULTS A total of 1474 patients requiring a pacemaker for symptomatic bradycardia were randomized to receive ventricular and 1094 to physiological pacemakers. The primary outcome was stroke or cardiovascular death. The study was completed in July 1998, and follow-up was extended to July 2001. At a mean follow-up of 6.4 years, there was no difference between treatment groups in the primary outcome of cardiovascular death or stroke. There was no significant difference in total mortality or stroke between groups. There was a significantly lower rate of development of atrial fibrillation in the physiological group, with a relative risk reduction of 20.1% (CI, 5.4 to 32.5; P=0.009). CONCLUSIONS The CTOPP extended study does not show a difference in cardiovascular death or stroke, or in total mortality, or in stroke between patients implanted with ventricular or physiological pacemakers over a mean follow-up of >6 years. However, there is a persistent significant reduction in the development of atrial fibrillation with physiological pacing.
منابع مشابه
Effects of Physiological Pacing During Long-Term Follow-Up
Background—The Canadian Trial of Physiological Pacing (CTOPP) reported that the risk of stroke or cardiovascular death was similar between patients receiving ventricular versus physiological pacemakers at the end of the original follow-up period of 3 years. However, the occurrence of atrial fibrillation was significantly less frequent with physiological pacemakers. To assess a potential delayed...
متن کاملRelationship between pacemaker dependency and the effect of pacing mode on cardiovascular outcomes.
BACKGROUND A recently completed trial, the Canadian Trial of Physiological Pacing (CTOPP), showed that physiological pacing did not significantly reduce mortality, stroke, or heart failure hospitalization, but it did show that atrial fibrillation occurred less frequently in patients with physiological pacing. Many pacemaker patients experience only transient bradyarrhythmias with an adequate un...
متن کامل[Clinical safety and efficacy of single-chamber atrial pacing in sick sinus syndrome: long-term follow-up].
INTRODUCTION AND OBJECTIVES Although atrial pacing is a more physiological mode of stimulation in sinus node dysfunction, the pacing modes most often are used DDD and VVI. The aim of our study was to demonstrate that AAI/AAIR pacing is effective and safe by analyzing the complications and mortality of this pacing mode in a long-term follow-up study. PATIENTS AND METHOD Between 1982 and 2000 d...
متن کاملPermanent Parahisian Pacing
Right Ventricular Apical permanent pacing could have negative hemodynamic effects. A physiologic pacing modality should preserve a correct atrio-ventricular and interventricular synchronization. This can be obtained through biventricular pacing, left ventricular pacing, or from alternative right ventricular pacing sites. Direct His Bundle Pacing (DHBP) was documented as reliable and effective f...
متن کاملLong-term follow-up of single-lead VDD pacing.
Long-term outcomes of single-lead VDD pacing were studied retrospectively and partly prospectively. Records were analysed of 81 patients out of 133 in whom a single-lead VDD pacemaker was implanted between January 1993 and December 1997 and who attended a follow-up clinic more than two years after the implant. Forty-eight of them attended a prospective follow-up 54 +/- 15 months after the impla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 109 3 شماره
صفحات -
تاریخ انتشار 2004