High Resolution Cavity BPM for ILC Final Focal System (IP-BPM)

نویسندگان

  • Tomoya Nakamura
  • Yosuke Honda
  • Yoichi Inoue
  • Toshiaki Tauchi
  • Junji Urakawa
  • Tomoyuki Sanuki
  • Sachio Komamiya
چکیده

Figure 1: IP-BPM Block ATF2 is an extension of ATF, a test facility for ILC accelerator development. ATF is the only facility today which can achieve beam emittance of the ILC specification. Experimental studies for ILC final focus is planned at ATF2, and is starting its operation at October, 2008. There are two main goals for ATF2. First, achievement of 35 nm beam size at the IP. Second, control of beam position in 2 nm precision at the IP. Old model cavity BPMs at ATF have achieved 17 nm position resolution so far [2]. But to achieve the two goals, a BPM of 2 nm position resolution (IP-BPM) is required at ATF2. We have fabricated two hot models of IP-BPM, and tested its performance at ATF.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cold Cavity BPM R&D for the ILC

A cold L-Band cavity BPM for installation in a SCRF cryomodule is currently under development at Fermilab. The BPM has to meet the ILC BPM specifications, i.e. < 1 μm single bunch, single pass resolution, going along with sufficient accuracy and reproducibility. Real estate limitations and the superconductive RF environment require some special considerations for this design.

متن کامل

The Electromagnetic Background Environment for the Interaction-point Beam Feedback System at the International Linear Collider

The Interaction Point (IP) feedback system is essential for maintaining the luminosity at the International Linear Collider (ILC). It is necessary to demonstrate the performance of the feedback beam position monitor (BPM) in an electron-positron pair background similar to that expected in the ILC interaction region (IR). We have simulated the ILC beam-beam interactions and used a GEANT model of...

متن کامل

Linac Coherent Light Source Undulator Rf Bpm System *

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of...

متن کامل

Cockcroft 07-33 ELECTROMAGNETIC BACKGROUND TESTS FOR THE ILC INTERACTION-POINT FEEDBACK SYSTEM

We present results obtained with the T-488 experiment at SLAC Endstation A (ESA). A material model of the ILC extraction-line design was assembled and installed in ESA. The module includes materials representing the mask, beamline calorimeter, and first extraction quadrupole, encompassing a stripline interaction-point feedback system beam position monitor (BPM). The SLAC high-energy electron be...

متن کامل

Comparison of Stripline and Cavity Beam Position Monitors

Operational principles of stripline and pill-box cavity beam position monitors (BPMs) are discussed. Their theoretically best achievable position and time resolutions are computed. Numbers are estimated using design values of the proposed e+e− linear collider TESLA. Introduction Important characteristics of a beam position monitor (BPM) are position and time resolutions. Position resolution is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008