Automated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.
نویسندگان
چکیده
OBJECTIVES To create a fully automated, combined perimetry program consisting of a static examination and a kinetic examination, and to compare the results of this test with standard static and kinetic visual fields (VFs). METHODS Fifty-six patients (74 eyes) undergoing neuro-ophthalmic or glaucoma evaluation who had standard static or kinetic perimetry examinations underwent the combined perimetry test. This automated, combined test, performed on the Octopus 101 perimeter, consisted of a static tendency-oriented perimetry examination and a preprogrammed kinetic examination. Three masked physician reviewers independently classified all of the VFs. The VF pairs were considered a match if the consensus descriptions of the standard and combined VFs matched. RESULTS Thirty-seven eyes underwent evaluation for neuro-ophthalmic disease (comparison standard test, 20 static and 17 kinetic) and 37 for glaucoma (comparison standard test, 17 static and 20 kinetic). The VP pairs matched in 32 eyes (86%) in the neuro-ophthalmic group and 28 (76%) in the glaucoma group. On inspection by a fourth reviewer, many of the nonmatching VF pairs were those for which a consensus was not reached, but still conveyed similar information. Two glaucomatous eyes demonstrated central scotomata not delineated by the combined examination findings. Two subtle nasal steps were detected solely by the combined examination. The combined test ranged in time from 6 to 12 minutes per eye. CONCLUSIONS The Octopus 101 perimeter can be used to create an automated test that combines the advantages of static and kinetic perimetry and produces equivalent results while not requiring examiner expertise.
منابع مشابه
Can Swedish interactive thresholding algorithm fast perimetry be used as an alternative to goldmann perimetry in neuro-ophthalmic practice?
OBJECTIVE To assess the potential role of Swedish Interactive Thresholding Algorithm (SITA) Fast computerized static perimetry, compared with that of Goldmann manual kinetic perimetry (GVF), for reliably detecting visual field defects in neuro-ophthalmic practice. BACKGROUND Automated visual field testing is challenging in patients with poor visual acuity or severe neurological disease. In th...
متن کاملComparison of Automated Kinetic and Static Visual Fields in Neuro-ophthalmology Patients
Eighty-three patients with various neuro-ophthalmic diseases were submitted to a standard automated protocol including kinetic and static perimetry The kinetic protocol included one peripheral, one intermediate and one central isopter and a blind spot contour determination The static protocol included fast thresholding of 80 points within the pericentral field and a 4-2-2-2 foveolar threshold d...
متن کاملComparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...
متن کاملAutomated achromatic perimetry
Visual field (VF) testing is an important diagnostic tool for Glaucoma. The current gold standard for VF testing is automated perimetry. This article is an attempt to familiarize the reader with components of an achromatic (white on white) automated perimetry printout. It addresses use of Humphrey perimeter to interpret the results. For the purpose of this review, a PubMed search was made using...
متن کاملSensitivity and specificity of frequency doubling perimetry in neuro-ophthalmic disorders: a comparison with conventional automated perimetry.
PURPOSE Frequency-doubling technology (FDT) perimetry was developed as a screening test for glaucoma. Patients with damage to the neuro-ophthalmic sensory visual pathways have different patterns of visual loss than patients with glaucoma. The current study was designed to determine the sensitivity and specificity of FDT as a screening test, compared with conventional automated perimetry (CAP) i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 124 3 شماره
صفحات -
تاریخ انتشار 2006