A New Control Algorithm of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Supply Conditions

نویسنده

  • K. Shabana
چکیده

To achieve maximum possible power factor and by keeping total harmonic distortion (THD) within the acceptable limit. A new control algorithm of shunt active power filter under distorted grid voltage and unbalanced supply conditions is proposed. A new control algorithm renders the optimal compromise between harmonic free (HF) and unity power factor (UPF) by keeping the total harmonic distortion (THD) of the source current within the standard range. In this paper, a new control approach for a three-phase fourwire shunt active power filter with PI and FUZZY controller under distorted grid voltage and unbalanced supply conditions is proposed. The algorithm employs a one-step process to get the conductance factors (only three). The extracted balanced set of voltages is multiplied with the constant conductance factors to get the required source currents. Using lagrangian technique mathematical formulas are derived for the conductance factors. Synchronous reference frame (SRF) theory is used to extract a balanced set of voltages from asymmetrical and distorted supply voltage conditions. Results acquired by simulations with Matlab/Simulink shows that the proposed control algorithm is very flexible and effective under steady and dynamic load conditions when compared to iterative OCA. Key TermsShunt Active power filter (SAPF), unity power factor (UPF), total harmonic distortion (THD), PI controller, fuzzy controller.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Control Algorithm of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Supply Conditions

To achieve maximum possible power factor and by keeping total harmonic distortion (THD) within the acceptable limit. A new control algorithm of shunt active power filter under distorted grid voltage and unbalanced supply conditions is proposed. A new control algorithm renders the optimal compromise between harmonic free (HF) and unity power factor (UPF) by keeping the total harmonic distortion ...

متن کامل

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

Reactive and Active Power Control of Grid WECS Based on DFIG and Energy Storage System under both Balanced and Unbalanced Grid Conditions

This paper focuses on improving the active and reactive power control of Wind Energy Conversion System (WECS) by employing the Battery Energy Storage System (BESS) and controlling the frequency and voltage regulation instantaneously. The proposed power control scheme is composed of two control loops so that they are implemented and designed for active power control and controlling the reactive ...

متن کامل

Real-Time Control of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Load Condition Using Self Tuning Filter

In this study, an alternative control method is proposed to improve the harmonic suppression efficiency of the active power filter in a distorted and unbalanced power system to compensate the perturbations caused by unbalanced non-linear loads. The proposed method uses a selftuning filter (STF) to process the grid voltage in order to provide a uniform reference voltage to obtain the correct ang...

متن کامل

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015