Evaluation of in vitro glistening formation in hydrophobic acrylic intraocular lenses
نویسندگان
چکیده
PURPOSE To evaluate the impact of continuous manufacturing process improvements on glistening formation in AcrySof hydrophobic acrylic intraocular lenses (IOLs) by comparing lenses manufactured in 2003 with lenses manufactured in 2012. METHODS Glistenings were experimentally created as aqueous-filled microvacuoles utilizing an accelerated laboratory method by immersing the lens in water at 45°C for 24 hours and then reducing the temperature to 37°C for 2.5 hours. To determine the impact of continuous improvements on glistening formation, AcrySof IOLs (Alcon Laboratories, Inc) Model SB30 AL manufactured in 2003 were compared with AcrySof IOLs Model SN60 WF manufactured in 2012. RESULTS Glistenings were present in all lenses after the accelerated microvacuole test method. The mean microvacuole density for IOLs manufactured in 2003 was 315.7 microvacuoles per square millimeter (MVs/mm(2)) with a glistening severity less than 100 MVs/mm(2) in 1.0% of the IOLs. The mean microvacuole density for IOLs manufactured in 2012 was 39.9 MVs/mm(2) with a glistening severity less than 100 MVs/mm(2) in 95.2% of the IOLs. Laboratory-induced microvacuole density was significantly lower in IOLs manufactured in 2012 (mean 39.9 MVs/mm(2)) relative to IOLs manufactured in 2003 (mean 315.7 MVs/mm(2)) as indicated by the Wilcoxon test of significance (P < 0.0005). CONCLUSION AcrySof IOLs recently manufactured in 2012 demonstrated a significant reduction in glistening density (87% reduction in mean density) as a result of continuous manufacturing process improvements compared with IOLs manufactured in 2003.
منابع مشابه
Assessment of new-generation glistening-free hydrophobic acrylic intraocular lens material.
PURPOSE To determine the hydrophobic, antiglistening, and bioadhesiveness properties of a new polymer, GF raw material, and to determine the suitability of this material for use in intraocular lenses (IOLs). SETTING University of Liege, Liege, Belgium. DESIGN Experimental study. METHODS Intraocular lenses made of the new hydrophobic acrylic material were tested and compared with reference...
متن کامل[Clinical and experimental observation of glistening in acrylic intraocular lenses].
PURPOSE To study whether the glistening on implanted acrylic intracular lenses increases or not. METHOD 1. Prospective study: We studied the glistening on 49 implanted acrylic intraocular lenses, particularly the time of appearance and increase after glistening appeared. 2. EXPERIMENT We kept an intraocular lens immersed in saline solution at 50 degrees centigrade for two hours and then mov...
متن کاملAnalysis of glistenings in hydrophobic acrylic intraocular lenses on visual performance.
AIM To assess patients' visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses (IOLs) (Alcon) 2 years postoperatively. METHODS This cross section trial included 120 eyes with one piece IOL at 2 years postoperatively. Glistening was classified in 4 groups, ranging from 0 (none) to 3 (most evident) according to their severity in IOLs optics observed under a...
متن کاملAnterior Segment Intraocular Lens Edge Profiles of Currently Available Intraocular Lenses and Recent Improvements
We evaluated the microstructure of the edges of currently available foldable intraocular lenses (IOLs). The methodology used assisted an IOL manufacturer (Hoya, Japan) to optimise the edge profile of its lenses. Ten designs of hydrophobic acrylic, six designs of silicone and 24 designs of hydrophilic acrylic IOLs were imaged under scanning electron microscopy (SEM), and the photographs were imp...
متن کاملFindings of an experimental study in a rabbit model on posterior capsule opacification after implantation of hydrophobic acrylic and hydrophilic acrylic intraocular lenses
PURPOSE Study on cell growth on the posterior capsule after implantation of hydrophobic acrylic (Acrysof SA 60 AT) and hydrophilic acrylic (Akreos Disc) intraocular lenses (IOL) in a rabbit model and comparison of posterior capsule opacification (PCO). METHODS Phacoemulsification was performed in 22 rabbit eyes, and two different IOL types (Acrysof SA60 AT and Akreos Disc) were implanted. The...
متن کامل