Reliability, minimal detectable change, and normative values for tests of upper extremity function and power.

نویسندگان

  • Rodney J Negrete
  • William J Hanney
  • Morey J Kolber
  • George J Davies
  • Megan K Ansley
  • Amanda B McBride
  • Amber L Overstreet
چکیده

The purpose of this study was to examine the test-retest reliability, minimal detectable change (MDC), and determine normative values of 3 upper extremity (UE) tests of function and power. One hundred eighty participants, men (n = 69) and women (n = 111), were tested on 3 UE strength and power maneuvers in a multicenter study to determine baseline normative values. Forty-six subjects returned for a second day of testing within 5 days of the initial assessment for the reliability component of the investigation. Explosive power was assessed via a seated shot-put test for the dominant and nondominant arms. Relationships between the dominant and nondominant arms were also analyzed. A push-up and modified pull-up were performed to measure the amount of work performed in short (15-second) bursts of activity. The relationship between the push-up and modified pull-up was also determined. Analysis showed test-retest reliability for the modified pull-up, timed push-up, dominant single-arm seated shot-put tests, and nondominant single-arm seated shot-put tests to be intraclass correlation coefficient(3,1) 0.958, 0.989, 0.988, and 0.971, respectively. The MDC for both the push-up and modified pull-up was 2 repetitions. The MDCs for the shot put with the dominant arm and the nondominant arm were 17 and 18 in., respectively. The result of this study indicates that these field tests possess excellent reliability. Normative values have been identified, which require further validation. These tests demonstrate a practical and effective method to measure upper extremity functional power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke

Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...

متن کامل

Test-retest Reliability of the Closed Kinetic Chain Upper Extremity Stability Test (ckcuest) in Adolescents: Reliability of Ckcuest in Adolescents.

BACKGROUND The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. PURPOSE The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clini...

متن کامل

Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects

  Abstract   Background: Postural instability has been identified as a potential precursor of   falls in elderly subjects. Postural stability in quiet stance is commonly assessed with   center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure   (COP) measures in the elderly subjects.   Met...

متن کامل

The reliability of side to side measurements of upper extremity activity levels in healthy subjects

BACKGROUND In both clinical and occupational settings, ambulatory sensors are becoming common for assessing all day measurements of arm motion. In order for the motion of a healthy, contralateral side to be used as a control for the involved side, the inherent side to side differences in arm usage must be minimal. The goal of the present study was to determine the reliability of side to side me...

متن کامل

Persian Translation, Internal Consistency and Reliability of Wolf Motor Function Test

Background: Wolf Motor Function Test (WMFT) is used in the assessment of upper extremity motor function in stroke patients. This scale contains 15 items and assesses joint-segment movements and functional tasks. Objectives: Translation and assessment of internal consistency and reliability of the Persian version of WMFT in Iranian stroke patients. Materials and Methods: After translation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of strength and conditioning research

دوره 24 12  شماره 

صفحات  -

تاریخ انتشار 2010