Uncertainty evaluation of the caesium fountain clock PTB-CSF2

نویسندگان

  • V. Gerginov
  • N. Nemitz
  • S. Weyers
  • R. Schröder
  • D. Griebsch
  • R. Wynands
چکیده

The uncertainty evaluation of CSF2, the second caesium fountain primary frequency standard at PTB, is presented. The fountain uses optical molasses to cool atoms down to 0.6μK. The atoms are launched vertically in a moving optical molasses, and state-selected in the |F = 3,mF = 0〉 hyperfine ground state. During their ballistic flight, the atoms interact twice with a microwave field, thus completing the Ramsey interaction. With a launch height of 36.5 cm above the cavity center, the central Ramsey fringe has a width of 0.9Hz. About 3 × 10 atoms, 30% of the initial number in the |F = 3,mF = 0〉 state, are detected after their second interaction with the microwave field. Stabilizing the microwave frequency to the center of the central Ramsey fringe, a typical relative frequency instability of 2.5 × 10 (τ/s) −1/2 is obtained. The CSF2 systematic uncertainty for realizing the SI second is estimated as 0.80× 10. First comparisons with the fountain CSF1 at the Physikalisch-Technische Bundesanstalt and other fountain frequency standards worldwide demonstrate agreement within the stated uncertainties. This is an author-created, un-copyedited version of an article accepted for publication in Metrologia. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at http://dx.doi.org/10.1088/0026-1394/47/1/008. Uncertainty evaluation of the caesium fountain clock PTB-CSF2 2

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NPL Cs fountain frequency standards and the quest for the ultimate accuracy

NPL operates a system of two primary caesium fountain clocks consisting of a fully characterised standard NPL-CsF2 together with a new standard NPL-CsF3, which has recently become operational. Both fountains feature a single-stage vapour-loaded magneto-optical trap as the source of cold atoms and an approximate cancellation of the potentially large cold collision frequency shift. As a result, t...

متن کامل

A Calcium Optical Frequency Standard with Ultracold Atoms: Approaching 10−15 Relative Uncertainty

An optical frequency standard based on an ensemble of neutral calcium atoms laser-cooled to 12 μK has been realized. By using ultracold atoms, one major previous source of uncertainty, the residual Doppler effect, was reduced. We show that cold collisions contribute a negligible amount to the uncertainty. The influence of a temporal evolution of the phase of the laser pulses used to interrogate...

متن کامل

Cancellation of the collisional frequency shift in caesium fountain clocks.

We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F=4,mF=0) atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement in ...

متن کامل

Performance of the PTB reconstructed primary clock CS1 and an estimate of its current uncertainty

The paper describes the current performance of the primary clock CS1 of the Physikalisch-Technische Bundesanstalt (PTB). The clock employs a thermal atomic beam and magnetic state selection. After major reconstruction during 1995 and 1996, routine clock operation was restarted in May 1997. Results of comparisons with UTC(PTB) and other internationally recognized time scales are presented. An ev...

متن کامل

Initial atomic coherences and Ramsey frequency pulling in fountain clocks

In the uncertainty budget of primary atomic cesium fountain clocks, evaluations of frequency-pulling shifts of the hyperfine clock transition caused by unintentional excitation of its nearby transitions (Rabi and Ramsey pulling) have been based so far on an approach developed for cesium beam clocks. We re-evaluate this type of frequency pulling in fountain clocks and pay particular attention to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010