AIMS We investigated the effectiveness of ozone (aqueous and gaseous) treatment as an alternative sanitizing technology to common conventional disinfectants in reducing the microbial contamination of both water and air. METHODS Ozone was added for 20 minutes to a well-defined volume of water and air by the system named "Ozonomatic®". The effectiveness of ozonation was determined by counting CFU/ m3 or ml of bacteria present in samples of air or water collected before (T0) and after (T1) the addition of ozone and comparing the microbial load of different bacteria present in ozonized and nonozonized samples. RESULTS When the ozonisation equipment was located at 30 cm from the surface of the water in the bath tub in which the bacteria investigated were inoculated, the treatment was able to reduce the total microbial load present in the aerosol by 70.4% at a temperature of 36°C for 48 hours. Conversely, at 22°C for 5 days, only a modest decrease (9.1%) was observed. Escherichia coli and Pseudomonas aeruginosa were completely eliminated. A 93.9% reduction was observed for Staphylococcus aureus, followed by Streptococcus faecalis (25.9%). The addition of ozone to water was able to almost eliminate Staphylococcus aureus (98.9% reduction) and also to exert a strong impact on Legionella pneumophila (87.5% reduction). Streptococcus faecalis and Pseudomonas aeruginosa showed a decrease of 64.2% and 57.4%, respectively. Conversely, only a 26.4% reduction was observed for the bacterium Escherichia coli. This study showed that the addition of ozone in the air exerted a modest reduction on microbial load at 36°C, whereas no effect was observed at 22°C. CONCLUSIONS Aqueous and gaseous ozone treatments were effective against microbial contaminants, reducing the CFU of the microorganisms studied. These results confirm the efficacy of the ozone disinfection treatment of both water and air; particularly, it constitutes an extremely promising alternative, allowing the possibility to reuse contaminated water.
منابع مشابه
Use of Ozone to Improve the Safety of Fresh Fruits and Vegetables
Traditional technology utilizes water with or without a sanitizing agent to wash fresh fruits and vegetables. Chlorine is the most widely used sanitizing agent available for fresh produce, but it has a limited effect in killing bacteria on fruit and vegetable surfaces. The most that can be expected at permitted concentrations is a 1to 2-log population reduction (Sapers, 1998). Furthermore, the ...
متن کاملCost and Performance Evaluation of Treatment Technologies for MTBE-Contaminated Water
Treatment of Methyl Tert-Butyl Ether (MTBE) from contaminated surface and groundwater supplies presents specific challenges due to the physicochemical properties of MTBE which depend strongly on its hydrophilic nature, and translate into a high solubility in water, very low HenryÕs constant and very low affinity for common adsorbents. In this study we evaluate two common treatment technologies,...
متن کاملComparison of ozone and chlorine in low concentrations as sanitizing agents of chicken carcasses in the water immersion chiller.
The aim of this study was to investigate the effects of the use of chlorine or ozone as sanitizing agents in the water of chicken immersion chilling, using the residual levels usually applied in Brazil (1.5 ppm), comparing the effects of these treatments on the microbiological, physicochemical, and sensory characteristics of carcasses. Chicken carcasses were chilled in water (4°C) with similar ...
متن کاملInactivation of Escherichia Coli O157:h7 on Inoculated Alfalfa Seeds during Exposure to Ozonated or Electrolyzed Oxidizing Water
Alfalfa sprouts contaminated with Escherichia coli O157:H7 and Salmonella have been implicated in a number of foodborne disease outbreaks in recent years. Seeds are attributed to be the main source of contamination for sprouts. Data from studies on the treatment of E. coli O157:H7 inoculated alfalfa seeds with ozonated and electrolyzed oxidizing (EO) water were used to develop models for predic...
متن کاملStatus and prediction of ozone as an air pollutant in Ahvaz City, Iran
In the present study, air quality analyses for ozone (O3) were conducted in Ahvaz, a city in the south of Iran. The measurements were taken from 2009 through 2010 in two different locations to prepare average data in the city. Relations between the air pollutant and some meteorological parameters were calculated statistically using the daily average data. The wind data (velocity, direction), re...
متن کامل