The DIN/ISO Definition and a Measurement Procedure of SW-Efficiency
نویسنده
چکیده
and foreword: People like to assign the attribute speed (i. e. performance) not only to hardware but also to software. But software does not have an attribute speed. Software defines for each user initiated task a sequence of information processing steps (machine instructions) to be performed. A suitable term for the aspect under construction can only be found when having a second imlementation (Imp2) of the application on the same hardware. We have to perform two performance measurements of the data processing system. Measurement 1, using the first implementation (Imp1), yields the performance value P1. Measurement 2, using the second implementation (Imp1), yields the performance value P2. To find a term describing the property of the software we compare P1 to P2. This yields a measure of „how good“ Imp2 transforms the task submitted into a sequence of machine instructions compared to Imp1: Imp2 is less or more efficient than Imp1.
منابع مشابه
Improvements in calculating the loudness of time varying sounds
Recently, a new ISO standard for loudness of arbitrary sounds ISO 532-1 (1) was proposed for the revision of ISO 532:1975 section 2 (method B) (2). It is based on DIN 45631/A1:2010 (3), which includes the widely used standard DIN 45631:1991 (4) for stationary sounds as a special case. ISO 532-1 eliminates uncertainties of existing standards by strictly defining the complete procedure of loudnes...
متن کاملLot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197.
BACKGROUND Accurate and reliable blood glucose (BG) measurements require that different test strip lots of the same BG monitoring system provide comparable measurement results. Only a small number of studies addressing this question have been published. METHODS In this study, four test strip lots for each of five different BG systems [Accu-Chek® Aviva (system A), FreeStyle Lite® (system B), G...
متن کاملSystem accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.
BACKGROUND The accuracy of systems for self-monitoring of blood glucose is important, as reliable measurement results are a prerequisite for therapeutic decisions. METHODS This system accuracy evaluation study was performed according to DIN EN ISO 15197:2003 for 43 Conformité Européenne (CE)-labeled blood glucose (BG) monitoring systems. Measurement results of each system were compared with r...
متن کاملارزیابی پارامترهای عملکردی در فیلترهای هپا در یک صنعت دارویی(مطالعه موردی1394)
Abstract: Background and aims: Nowadays, cleanrooms have become impartible parts of an industry with sensitive products. Sources of contamination in cleanrooms are impaired performance and quality sensitive products in the cleanrooms .The aim of this study was to evaluate the efficiency of HEPA filter and check the concentration and number of airborne particles in cleanrooms for pharmaceutic...
متن کاملبررسی بخش مدارک پزشکی بیمارستانهای آموزشی دانشگاه علوم پزشکی ایران با معیارهای سیستم مدیریت کیفیت، سال1387
Introduction: Quality management is an intelligent, steady and continuous procedure with a synergic effect on organization goals resulting in customer satisfaction, increased efficiency and enhanced ability to compete in the market. The procedure is considered as an improvement in traditional methods of business and an established technique which ensures organization survival in today’s competi...
متن کامل