The current state of bearing surfaces in total hip replacement.
نویسندگان
چکیده
We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual's functional demands.
منابع مشابه
Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Meta...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملA critical appraisal of the evidence regarding the choice of common bearing couples available for total hip arthroplasty.
There are a variety of materials used in bearing components in total hip replacement (THR). Metal-on-polyethylene replacements, having undergone small technical refinements in design over the last 30- 40 years, give, according to the Scandinavian hip register, very good 10-year outcomes. However, aseptic loosening, caused to a great extent by adverse biological local reactions, induced by wear ...
متن کاملSetting benchmark revision rates for total hip replacement: analysis of registry evidence.
OBJECTIVE To compare 10 year revision rates for frequently used types of primary total hip replacement to inform setting of a new benchmark rate in England and Wales that will be of international relevance. DESIGN Retrospective cohort study. SETTING National Joint Registry. PARTICIPANTS 239 000 patient records. MAIN OUTCOME MEASURES Revision rates for five frequently used types of total...
متن کاملCurrent state and future of joint replacements in the hip and knee.
Joint replacements of the hip and knee are among the most clinically successful operations. According to figures compiled by the American Academy of Orthopaedic Surgeons, the number of primary total hip replacements performed in the USA was 220,000 in 2003. This was 38% more than in 1996 and this number is expected to rise to 572,000 (plus another 97,000 revisions) by 2030. The number of primar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The bone & joint journal
دوره 96-B 2 شماره
صفحات -
تاریخ انتشار 2014