Ion Exchange Chromatography – Optimisation and Robustness Analysis Using Design of Experiments

نویسنده

  • Emelie Stenborg
چکیده

Proteins are often separated using ion-exchange chromatography. This method can however show poor resolution if not carefully optimised. This work aims to find all the parameters that affect the separation as well as determining which are critical. By using Design of Experiment the optimum separation is found and a robustness analysis is conducted. Polyclonal antibody Immunoglobulin G (IgG) and Bovine Serum Albumin (BSA) are separated on a strong anionexchange column. The parameters focused on are the elution gradient, pH, sample concentration, flow rate and sample size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoglobulin A Preparation from Human Pooled Plasma Using Plasma Fractionation and Ion Exchange Chromatography

Background: In this study we have prepared the IgA solution from normal human plasma using plasma fractionation and ion exchange chromatography. Materials and Methods: Using fractionation of plasma with cold ethanol (starting with 8% ethanol), fraction III was prepared as a suitable source for IgA preparation. Then it was treated with caprylic acid for separation of impurities. For enrichm...

متن کامل

Isolation and purification of albumin from human plasma by direct and combined approach of ion-exchange chromatography and comparison of the final products quality obtained by both methods

Background: Due to multiple roles of albumin in the body, injection of its medicinal product as one of the therapeutic or management strategies under conditions such as severe bleeding, burns, liver failure, and neonatal hemolytic diseases is on the physicians' agenda. Considering that albumin is the most abundant plasma protein, designing an appropriate method to purify it is highly important....

متن کامل

Development and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes

Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this m...

متن کامل

Optimization of Dynamic Binding Capacity of Anion Exchange Chromatography Media for Recombinant Erythropoietin Purification

  Background:The dynamic binding capacity (DBC) of a chromatography matrix in protein purification is the amount of the total protein absorbed into the matrix, before occurrence of a significant break in the breakthrough curve. Optimization of the process criteria for maximum DBC avoids extra process scale-up and reduces ...

متن کامل

Optimisation of wire-cut EDM process parameter by Grey-based response surface methodology

Wire electric discharge machining (WEDM) is one of the advanced machining processes. Response surface methodology coupled with Grey relation analysis method has been proposed and used to optimise the machining parameters of WEDM. A face centred cubic design is used for conducting experiments on high speed steel (HSS) M2 grade workpiece material. The regression model of significant factors such ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005