Direct Current Make and Break Thresholds far Pacemaker Electrodes on the Canine Ventricle

نویسنده

  • Egbert Dekker
چکیده

Thresholds to anodal make, anodal break, cathodal make and cathodal break have been studied throughout the cardiac cycle in 13 dogs under pentobarbital anesthesia. Unipolar direct current pulses were applied through epicardial pacemaker electrodes to the left ventricle. Make and break responses were separated by letting the break and make occur in the refractory periods of the following and preceding cycle, respectively. Four distinct threshold interval curves were obtained from each of 17 electrodes. The anodal break and cathodal break curves showed an early diastolic dip. Dips were deepest in the anodal break curves. These also had the shortest effective refractory period. Thresholds for cathodal make and anodal make first dipped steeply, then gradually sloped down towards end-diastolic levels. The magnitude of end-diastolic mean threshold values increased in the following order: cathodal make, anodal make, cathodal break, anodal break. Comparison of threshold interval curves for make and break responses with those for shorter rectangular anodal and cathodal curves throughout the cardiac cycle supports the hypothesis that die threshold behavior to a short rectangular pulse is determined by whichever of two thresholds is lowest: make or break at that particular cycle interval. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct current make and break thresholds for pacemaker electrodes on the canine ventricle.

Thresholds to anodal make, anodal break, cathodal make and cathodal break have been studied throughout the cardiac cycle in 13 dogs under pentobarbital anesthesia. Unipolar direct current pulses were applied through epicardial pacemaker electrodes to the left ventricle. Make and break responses were separated by letting the break and make occur in the refractory periods of the following and pre...

متن کامل

Early Malfunction of Transvenous Pacemaker Electrodes

A 3-year study by three medical centers has revealed a 1-year electrode malfunction rate of 7.4%; most malfunctions occurred within the first 30 days. The incidence of unavoidable early malfunction (3.2%) fell within the 5% standards suggested by the committee report of the Inter-Society Committee on Heart Diseases. Incidences of obscure cause (3.2%) may be difficult to identify prospectively a...

متن کامل

Cutaneous sensory threshold stimulation with high frequency square-wave current. I. The relationship of electrode dimensions to the sensory threshold.

Numerous methods of studying the sensibility of the skin have been reported. Martin (1) described the threshold of faradic break shocks; Ollendorf (2) used hair strokes, pin pricks, heat and pressure with a probe in normal and abnormal skin to determine differences in sensation; Mayr (3) utilized the pressure of a water manometer on normal and syphilitic skin; Hardy and Wolff (4) introduced the...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

  In radiation therapy with high-energy photon beams (E > 10 MV) neutrons are generated mainly in LINACs head thorough (γ,n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the AAPMTG-34 report, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in the functioning of the pac...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005