Induction and detection of antibodies to squalene. II. Optimization of the assay for murine antibodies.

نویسندگان

  • Gary R Matyas
  • Mangala Rao
  • Carl R Alving
چکیده

An improved high throughput assay for measuring murine antibodies to squalene (SQE) is described. The assay is highly reproducible and sensitive and can detect 80 ng/ml of antibody to SQE. The assay, an ELISA, is similar to our previously described assay in which plates containing PVDF membranes were used [J. Immunol. Methods 245 (2000) 1]. The PVDF plates worked well for detection of murine monoclonal antibodies (mAbs) to SQE, but substantial PVDF plate variation was observed, resulting in significant loss of signal and reproducibility between different lots of plates. In the new assay, the PVDF plates were replaced with Costar round bottom 96-well sterile tissue culture plates. These latter plates, which are not normally used for ELISA assay, gave high absorbances for monoclonal antibodies and anti-SQE serum binding to SQE and low absorbances for solvent-treated wells. Other commercially available polystyrene ELISA plates were unsuitable, in that either the background was high or the absorbance for antibodies binding to SQE was low, or both. This change in plate from PVDF to polystyrene allowed the use of an ELISA plate washer, which dramatically increased the throughput rate over the hand-washed PVDF plates. The improved assay also replaced fetal bovine serum (FBS), which contained SQE in lipoproteins, with fatty acid-free bovine serum albumin (BSA) as the blocker/diluent. Fifteen nanomoles of SQE were selected as the optimal amount of SQE to add to the wells. The binding of monoclonal antibodies and anti-SQE serum was dependent upon both the amount of antibody added to the wells and the amount of SQE added to the wells. Antibody concentration curves were hyperbolic in shape, as seen with most other antibodies. Antibody binding first increased with SQE amount and then reached a plateau around 10 nmol of SQE/well. At high SQE amounts (>75 nmol/well), antibody binding decreased with the amount of SQE added. Using 3H-SQE, the amount of SQE bound to the wells increased linearly, up to 50 nmol of SQE added. Approximately 90% of the added SQE bound to the well. When amounts greater than 100 nmol of SQE were added, the amount of SQE bound to the wells was greatly reduced to approximately 5-10% of the added SQE. The assay was highly reproducible both from lot to lot of plates and from experiment to experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Production and Characterization of Murine Monoclonal Antibodies to Leishmania Gp63 Antigen

Background : Production of monoclonal antibodies to Leishmania antigens assists the identification and characterization of these organisms. Objective: Production of monoclonal antibodies against epitopes on the gp63. Methods: Two murine monoclonal antibodies to gp63 were produced and characterized. The reactions of both antibodies with soluble leishmanial antigens, purified gp63 and truncated r...

متن کامل

A multiple-antigen detection assay for tuberculosis diagnosis based on broadly reactive polyclonal antibodies

Objective(s): Detection of circulating Mycobacterium tuberculosis (M. tuberculosis) antigens is promising in Tuberculosis (TB) diagnosis. However, not a single antigen marker has been found to be widely expressed in all TB patients. This study is aimed to prepare broadly reactive polyclonal antibodies targeting multiple antigen markers (multi-target antibodies) and evaluate their efficacies in ...

متن کامل

Evaluation of effective factors in the optimization of immunization to achieve antibodies against RhD antigen in culture medium

Abstract Background and Objectives Antibody against RhD antigen is important in blood transfusion and clinical medicine. Therefore, in this study, the effective factors in the optimization of in vitro immunization to achieve immunized lymphocytes that produce antibodies were evaluated to obtain antibodies against RhD antigen in the culture medium. Materials and Methods In an experimental study...

متن کامل

Designing an enzyme-linked immunosorbent assay for detection of anti-penicillin antibodies levels in various species of animals in Khuzestan province, Iran

The penicillin allergy is being increasingly recognized as a significant public health problem. Immunological responses to penicillin and other beta-lactam antibiotics are classified as immediate and non-immediate responses. This research aimed to develop an enzyme-linked immunosorbent assay (ELISA) for the detection of the reactive antibody value against penicillin in various species of animals...

متن کامل

Development of a Western Blot Assay for Detection of Antibodies against HSV Using Purified HSV Virions Prepared by Sucrose Density Gradient

Objective(s) Herpes simplex viruses (HSVs) have widespread and ubiquitous prevalence in the human population and they have received a great deal of attention due to the range of diseases, they caused as a result of an infection. It seems that the fast and reliable diagnostic methods are needed for detecting the herpes simplex virus type 1 (HSV1) antibodies especially in patients with HSV encep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of immunological methods

دوره 267 2  شماره 

صفحات  -

تاریخ انتشار 2002