Evaluation of the PATHFAST Chemiluminescent Enzyme Immunoassay for Measuring Progesterone in Whole Blood and Serum of Mares

نویسندگان

  • Yuko TOISHI
  • Nobuo TSUNODA
  • Masaaki TAGAMI
  • Hiromitsu HASHIMOTO
  • Fumiki KATO
  • Tsukasa SUZUKI
  • Kentaro NAGAOKA
  • Gen Watanabe
  • Shota TOKUYAMA
  • Kiyoshi OKUDA
  • Kazuyoshi TAYA
چکیده

Evaluation of a new chemiluminescent enzyme immunoassay, the PATHFAST assay system (PATHFAST), for measurement of circulating progesterone in mares was performed. Five mares at the mid-luteal stage were administrated a single i.m. injection of prostaglandin F2α analog (PGF2α; cloprostenol 250 μg/ml), and then blood samples were collected from the jugular vein at 0, 15, 30 and 45 min, at one-hour intervals until 24 and at 48 hr via a catheter in the jugular vein. To monitor the physiological changes in circulating progesterone in mares after induced luteolysis, concentrations of progesterone in whole blood and serum samples were measured by PATHFAST. In addition, concentrations of progesterone in serum samples measured by PATHFAST were compared with those measured by radioimmunoassay (RIA) and enzyme immunoassay (EIA). Using PATHFAST, the serum concentrations of progesterone in mares correlated highly with those of whole blood samples (r=0.9672, n=88). The serum concentrations of progesterone as measured by PATHFAST correlated well with RIA (r=0.9654, n=88) and EIA (r=0.9323, n=112). An abrupt decline in circulating progesterone in whole blood samples was observed within 2 hr (50%), followed by a gradual decline until 48 hr later. The results for progesterone in whole blood samples correlated highly with those in serum samples, and the declining pattern paralleled that of the serum samples. These results demonstrated that PATHFAST is useful in the equine clinic as an accurate diagnostic tool for rapid assay of progesterone within 26 min, using unextracted whole blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PATHFAST, a novel chemiluminescent enzyme immunoassay for measuring estradiol in equine whole blood and serum

A novel chemiluminescent enzyme immunoassay system, PATHFAST, for the measurement of estradiol in horses was evaluated. The concentrations of estradiol in the whole blood and serum of mares were measured using PATHFAST and the estradiol concentrations measured by PATHFAST were compared with those measured by a time-resolved fluoro-immunoassay (FIA). To monitor physiological changes, serum estra...

متن کامل

Development of a point-of-care assay system for measurement of presepsin (sCD14-ST).

BACKGROUND The soluble CD14 subtype (sCD14-ST: renamed as presepsin) is a novel soluble CD14 molecule that is useful for diagnosing sepsis because sCD14-ST levels increase specifically in sepsis patients. METHODS A fully automated PATHFAST® Presepsin assay system based on a chemiluminescent enzyme immunoassay was developed for detecting presepsin in human whole blood. RESULTS The limit of b...

متن کامل

A rapid and quantitative D-Dimer assay in whole blood and plasma on the point-of-care PATHFAST analyzer.

The objective of this study was to evaluate the accuracy indices of the new rapid and quantitative PATHFAST D-Dimer assay in patients with clinically suspected deep-vein thrombosis (DVT). Eighty two consecutive patients (34% DVT, 66% non-DVT) with suspected DVT of a lower limb were tested with the D-Dimer assay with a PATHFAST analyzer. The diagnostic value of the PATHFAST D-Dimer assay (which ...

متن کامل

Evaluation of the chemiluminescent enzyme immunoassay system for the measurement of testosterone in the serum and whole blood of stallions

Testosterone (T) concentration is a useful indicator of reproductive function in male animals. However, T concentration is not usually measured in veterinary clinics, partly due to the unavailability of reliable and rapid assays for animal samples. In this study, a rapid chemiluminescent enzyme immunoassay system (CLEIA system) that was developed for the measurement of T concentration in humans...

متن کامل

O-5: Endocrinological and Morphological Evaluation of Vitrified-Warmed Ovarian Tissue

Background: Our aim was to evaluate the recovery rate of ovarian function and the activity of hypothalamus-hypophiseal- gonadal axis following transplantation of vitrified ovaries. Materials and Methods: Five weeks-old female Wistar Rats were distributed randomly in two experimental groups; Fresh Transplanted, Vitrified-Transplanted and 8 weeks-old female Wistar rats were considered as control ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2013