Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera.

نویسندگان

  • Barry Cense
  • Mircea Mujat
  • Teresa C Chen
  • B H Park
  • Johannes F de Boer
چکیده

Polarization-sensitive optical coherence tomography can be used to measure the birefringence of biological tissue such as the human retina. Previous measurements with a time-domain polarization-sensitive optical coherence tomography system revealed that the birefringence of the human retinal nerve fiber layer is not constant, but varies as a function of location around the optic nerve head. Here we present a spectral-domain polarization-sensitive optical coherence tomography system that uses a spectrometer configuration with a single line scan camera and a Wollaston prism in the detection arm. Since only one camera has to be synchronized with other components in the system, the design is simplified considerably. This system is 60 times faster than a time-domain polarization-sensitive optical coherence tomography system. Data was acquired using concentric circular scans around the optic nerve head of a young healthy volunteer and the acquisition time for 12 circular scans was reduced from 72 s to 1.2 s. The acquired data sets demonstrate variations in retinal thickness and double pass phase retardation per unit depth that were similar to data from the same volunteer taken with a time-domain polarization-sensitive system. The double pass phase retardation per unit depth of the retinal nerve fiber layer varied between 0.18 and 0.40 degrees/mum, equivalent to a birefringence of 2.2 * 10(-4) and 4.8 * 10(-4) respectively, measured at 840 nm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single camera spectral domain polarization-sensitive optical coherence tomography using offset B-scan modulation.

We report a simple implementation to acquire spectral domain polarization-sensitive optical coherence tomography (PSOCT) using a single camera. By combining a dual-delay assembly in the reference arm and offset B-scan in the sample arm, the orthogonal vertical- and horizontal-polarized images were acquired in parallel and spatially separated by a fixed distance in the full range image space. Th...

متن کامل

High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstrate the proposed method, we use two spectrometers built in a 1310 nm-band SDOCT...

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method.

Fiber-based high-speed polarization-sensitive Fourier domain optical coherence tomography (PS-FD-OCT) is developed at 840 nm wavelength using polarization modulation method. The incident state of polarization is modulated along B-scan. The spectrometer has a polarizing beamsplitter and two line-CCD cameras operated at a line rate of 27.7 kHz. From the 0th and 1st orders of the spatial frequenci...

متن کامل

Hybrid retinal imager using line-scanning laser ophthalmoscopy and spectral domain optical coherence tomography.

We demonstrate for the first time the integration of two technologies, Spectral Domain Optical Coherence Tomography (SDOCT) and Line-Scanning Laser Ophthalmoscopy (LSLO) into a single compact instrument that shares the same imaging optics and line scan camera for both OCT and LSLO imaging. Co-registered high contrast wide-field en face retinal LSLO and SDOCT images are obtained non-mydriaticall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 2007