Measuring techniques in induced polarisation imaging
نویسندگان
چکیده
Multi-electrode geoelectrical imaging has become very popular and is used for many different purposes. For some of these, the inclusion of IP data would be desirable as it would allow the interpreter to distinguish between, e.g. sand formations with saltwater infiltration and clay formations or help delineate landfills. However, present-day IP measuring techniques require the use of nonpolarisable potential electrodes and special wire layout and are thus cumbersome and expensive. In this paper, we suggest making IP measurements with multi-electrode cables and just one set of steel electrodes. The polarisation potentials on the potential electrodes are corrected for by subtracting the polarisation potential measured when no primary current and no IP signal are present. Test measurements indicate that the polarisation potentials vary slowly and that the correction procedure is feasible. At two sites in southern Sweden, we have compared measurements with only stainless steel electrodes and measurements with both stainless steel and Pb–PbCl nonpolarisable electrodes using one or two sets of multicore cables, respectively. Almost no difference between the two data sets was observed. At one site, the charge-up effect on the potential electrodes was not important, while at the other site, the correction procedure was crucial. Though only two sites have been studied so far, it seems that time-domain IP imaging measurements can be taken with only steel electrodes and ordinary multicore cables. Coupling in the multicore cables has not presented any problems at the investigated sites where grounding resistances were moderate, making the coupling effect small. High grounding resistance sites have not yet been investigated. D 2002 Published by Elsevier Science B.V.
منابع مشابه
Non-conventional imaging systems for 3D digitization of transparent objects: Shape from polarization in the IR and shape from visible fluorescence induced UV
This paper presents a comparison between recent advances made in the field of non conventionnal imaging techniques for 3D digitization of transparent object. After a large survey, this paper will focus on two recent techniques later called : shape from Visible Fluorescence UV-induced and shape from polarisation in the IR which recently emerged. Results obtained with the technique of Scanning fr...
متن کاملOptically induced dynamic nuclear spin polarisation in diamond
The sensitivity of Magnetic Resonance Imaging (MRI) depends strongly on nuclear spin polarisation and, motivated by this observation, dynamical nuclear spin polarisation has recently been applied to enhance MRI protocols (Kurhanewicz, J., et al., Neoplasia 13, 81 (2011)). Nuclear spins associated with the C carbon isotope (nuclear spin I = 1/2) in diamond possess uniquely long spin lattice rela...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملSurface shape and reflectance analysis using polarisation
When unpolarised light is reflected from a smooth dielectric surface, it becomes partially polarised. This is due to the orientation of dipoles induced in the reflecting medium and applies to both specular and diffuse reflection. This thesis aims to exploit the polarising properties of surface reflection for computer vision applications. Most importantly, the thesis proposes novel shape and ref...
متن کاملMeasuring the temperature dependence of refractive index in water phantom for precise monitoring of the absorbed dose by radiation therapy techniques
In this paper, an experimental setup is used to measure the temperature dependence of the refractive index of a water phantom. In radiation calorimetry by laser beams and interferometric systems, the amount of change induced by radiation within the phantom can be accurately measured. Absorption of dose and the resulted change in temperature changes the refractive index within the material. In o...
متن کامل