Cone beam computed tomographic measurement of maxillary central incisors to determine prevalence of facial alveolar bone width ≥2 mm.

نویسندگان

  • Hessam Nowzari
  • Shervin Molayem
  • Ching Hsiu Ketty Chiu
  • Sandra K Rich
چکیده

BACKGROUND The initial thickness of maxillary bone has significant impact on the responding level of facial bone and soft tissue after extraction and immediate implant placement. A prevailing notion is that following implant placement in fresh extraction sites, at least 2 mm of facial bone is needed to prevent soft tissue recession, fenestration, and dehiscence. PURPOSE The purpose of this study was to use cone beam computed tomography (CBCT) to measure horizontal width of facial alveolar bone overlying healthy maxillary central incisors and to determine prevalence of bone thickness ≥2 mm. MATERIALS AND METHODS Tomographic data from 101 randomly selected patients were evaluated by two independent observers. Assessments were made of facial bone width at levels 1.0 to 10.0 mm apical to the bone crest. RESULTS Healthy maxillary central incisors (n= 202) were measured from 101 patient scans. The percent of teeth with facial bone ≥2 mm at levels 1, 2, 3, 4, and 5 mm from the bone crest was 0, 1.5, 2.0, 3.0, and 2.5%, respectively. Overall mean thickness of the bone was 1.05 mm for right and left central incisors combined. The range of individual measurements for all levels was 0 to 5.1 mm. The occurrence of ≥ 2 mm thickness bone measurements increased with increasing depth. However, mean widths observed at levels 6 to 10 mm from the crest ranged only 1.0 to 1.3 mm because of apparent fenestration occurrence (0 mm bone) in approximately 12% of teeth. Overall, no significant differences in bone thickness were found between ethnic, gender, age, or scan groups. CONCLUSIONS Using CBCT, occurrences of ≥2 mm maxillary facial alveolar bone were found on no more than 3% of root surfaces 1.0 to 5.0 mm apical to the bone crest in this sample of maxillary central incisors. The study evidenced prevalence of a thin facial alveolar bone (<2 mm) that may contribute to risk of facial bone fenestration, dehiscence, and soft tissue recession after immediate implant therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی دقت توموگرافی خطی در تعیین محل حفره بینی و سینوس ماگزیلاری1

Background and Aim: Accurate measurement of bone height and width is essential prior to dental implant placement. The method of surgery as well as, the type and size of implants are determined according to dimensions of the residual bone. The purpose of this study was to evaluate the accuracy of linear tomography in localization of the floor of nasal fossa and maxillary sinus, and to determine ...

متن کامل

Analysis of the root position of the maxillary incisors in the alveolar bone using cone-beam computed tomography

PURPOSE The purpose of this study was to measure the buccal bone thickness and angulation of the maxillary incisors and to analyze the correlation between these parameters and the root position in the alveolar bone using cone-beam computed tomography (CBCT). MATERIALS AND METHODS CBCT images of 398 maxillary central and lateral incisors from 199 patients were retrospectively reviewed. The roo...

متن کامل

Evaluation of root and alveolar bone development of unilateral osseous impacted immature maxillary central incisors after the closed-eruption technique.

INTRODUCTION In this study, we evaluated root and alveolar bone development in unilateral osseous impacted immature maxillary central incisors by cone-beam computed tomography before and after closed-eruption treatment, in comparison with naturally erupted contralateral immature maxillary central incisors. METHODS AND RESULTS The study included 30 patients, 20 boys and 10 girls, with a mean a...

متن کامل

Anatomic Situation of Posterior Superior Alveolar Artery in Cone-Beam Computed Tomography Images in Maxillary Molar Region

Introduction: Bleeding is an important complication during implant placement. The aim of this study was to evaluate the anatomic situation of the posterior superior alveolar artery (PSAA) in cone-beam computed tomography (CBCT) images in maxillary molar region in an Iranian population. Methods: In this descriptive cross-sectional study, CBCT scans of the edentulous regions of the posterior max...

متن کامل

Measuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique

Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2012