Safety and cleaning of medical materials and devices.

نویسندگان

  • K Merritt
  • V M Hitchins
  • S A Brown
چکیده

A study was undertaken to evaluate different procedures to safely remove microorganisms, protein, and mammalian cells from materials and provide a suitable method for cleaning and assessing effectiveness of cleaning medical devices for reuse or for analysis of failure. Safety considerations for the personnel performing the cleaning or handling the device after cleaning are important issues. Polystyrene plates (96 well) were used to simulate device surfaces not amenable to manual scrubbing. Staphylococcus epidermidis, Candida albicans, Escherichia coli, Pseudomonas aeruginosa, and oral flora were grown in the plates. The plates were stained with crystal violet and the optical densities recorded. The results indicated that E. coli did not adhere well and Pseudomonas formed clumps that were easily detached from the surface of the plates. However, S. epi, C. albicans, and the oral organisms formed adherent biofilms that were difficult to remove from the plates. Detergents with enzymes and sodium hypochlorite (NaOCl) bleach were both effective in removing the biofilm. Other detergents and surfactants were not effective. The aldehyde agents did not remove the organisms and made further cleaning difficult. Allowing the biofilm to dry first made cleaning very difficult. Only the NaOCl bleach could subsequently remove the dried or aldehyde fixed organisms from the wells. The same 96-well polystyrene plate format was used to measure the amount of protein and cell adherence as well as the effectiveness of subsequent cleaning. Bradford reagent was used to detect protein as a measure of the cleaning efficacy. As with the bacteria, NaOCl bleach was effective at removing the protein and cells that had been dried or fixed by formalin or alcohol, whereas detergent with enzymes was not very effective. This study confirmed that used medical devices, contaminated with microorganisms, protein, and/or mammalian cells, should not be allowed to dry before cleaning and that a thorough cleaning procedure should precede sterilization or disinfection (with the exception of NaOCl bleach which also cleans).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative study of the cleaning effect of various ultrasonic cleaners on ‎new, unused endodontic instruments

BACKGROUND AND AIM: This study was carried out to compare three different ultrasonic cleaner devices in the cleaning process of endodontic instruments by scanning electron microscope (SEM). METHODS: In this study, 120 unused brand new hand and rotary instruments were examined after removing from the sealed package. The instruments were randomly divided into six groups of 20 rotary or hand files...

متن کامل

A Study on Performance and Safety Tests of Defibrillator Equipment

Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the requ...

متن کامل

Why Should We Have a Periodic Safety and Performance Program for Medical Devices

Nowadays, more than 10,000 different types of medical devices can be found in hospitals.These devices used in medical centers and hospitals for monitoring and treatment of patients require periodic safety and performance checking in order to have confidence in their functioning and operation. Physicians need better accurate medical measurements in order to better diagnose diseases, monitor pati...

متن کامل

Removal of a Natural Toxin Surrogate from Water, Material Surfaces, and Reusable Medical Devices

Water and reusable medical device surfaces can be contaminated by natural toxins such as ricin either accidentally or intentionally. This report focuses on the removal of peanut lectin (PL), a ricin surrogate, from water and reusable medical devices and materials. An ELISA assay was used to determine if commercially available water filters could remove peanut lectin from water, and if commercia...

متن کامل

Survey of drinking water quality of household water treatment and public distribution network in Garmsar city, under the control of water safety plan

Background and Objective: Surface water and underground water quality in countries that facing dehydration have increased the interest of the community to use Household Water Treatment devices. The aim of this study was the evaluation of the quality of drinking water of Household Water Treatment devices and general distribution network in Garmsar, which is under the control of the water safety ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research

دوره 53 2  شماره 

صفحات  -

تاریخ انتشار 2000