Iterative correction of beam hardening artifacts in CT.

نویسندگان

  • G Van Gompel
  • K Van Slambrouck
  • M Defrise
  • K J Batenburg
  • J de Mey
  • J Sijbers
  • J Nuyts
چکیده

PURPOSE To reduce beam hardening artifacts in CT in case of an unknown x-ray spectrum and unknown material properties. METHODS The authors assume that the object can be segmented into a few materials with different attenuation coefficients, and parameterize the spectrum using a small number of energy bins. The corresponding unknown spectrum parameters and material attenuation values are estimated by minimizing the difference between the measured sinogram data and a simulated polychromatic sinogram. Three iterative algorithms are derived from this approach: two reconstruction algorithms IGR and IFR, and one sinogram precorrection method ISP. RESULTS The methods are applied on real x-ray data of a high and a low-contrast phantom. All three methods successfully reduce the cupping artifacts caused by the beam polychromaticity in such a way that the reconstruction of each homogeneous region is to good accuracy homogeneous, even in case the segmentation of the preliminary reconstruction image is poor. In addition, the results show that the three methods tolerate relatively large variations in uniformity within the segments. CONCLUSIONS We show that even without prior knowledge about materials or spectrum, effective beam hardening correction can be obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Beam Hardening Correction with an Iterative Scheme Using an Exact Backward Projector and a Polychromatic Forward Projector

In computed tomography (CT), reconstructions from conebeam (CB) data acquired with a polychromatic X-ray device show so called beam hardening artifacts. Beam hardening artifacts are highly undesirable for a medical diagnosis, because details in the reconstructed image are severely disturbed or completely lost. In this work, we demonstrate the significant reduction of beam hardening artifacts by...

متن کامل

Iterative Reconstruction for Quantitative Tissue Decomposition in Dual-Energy CT

Quantitative tissue classification using dual-energy CT has the potential to improve accuracy in radiation therapy dose planning as it provides more information about material composition of scanned objects than the currently used methods based on single-energy CT. One problem that hinders successful application of both singleand dualenergy CT is the presence of beam hardening and scatter artif...

متن کامل

An iterative approach to the beam hardening correction in cone beam CT.

In computed tomography (CT), the beam hardening effect has been known to be one of the major sources of deterministic error that leads to inaccuracy and artifact in the reconstructed images. Because of the polychromatic nature of the x-ray source used in CT and the energy-dependent attenuation of most materials, Beer's law no longer holds. As a result, errors are present in the acquired line in...

متن کامل

Expert-guided CT beam hardening correction for heterogeneous natural materials

We present a new method for correcting beam hardening artifacts in CT data. Software correction typically consists of a polynomial transform of the raw data, but determining optimal coefficients is not straightforward, especially if the material is not well known or characterized, as is the usual case when imaging geological materials. Our method lets an expert user guide an iterative optimizat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 38 S1  شماره 

صفحات  -

تاریخ انتشار 2011