Spectrophotometric and potentiometric determination of piroxicam and tenoxicam in pharmaceutical preparations.

نویسندگان

  • Mohamed A El-Ries
  • Gehad Mohamed
  • Shaeban Khalil
  • Manal El-Shall
چکیده

Two simple and accurate methods are described for the determination of piroxicam and tenoxicam in their pharmaceutical preparations. The spectrophotometric method involves the oxidation of these drugs with potassium iodate in acid medium with the liberation of iodine and subsequent extraction with cyclohexane followed by measuring the absorbance at lambda=522 nm. Beer's law is obeyed in the concentration range of 0.05-1.1 and 0.05-0.6 mg x ml(-1) for piroxicam and tenoxicam, respectively. The apparent molar absorptivities of the resulting coloured products are found to be 2.7 x 10(3) and 2.5 x 10(3) l mol(-1) x cm(-1), whereas Sandell sensitivities are 0.012 and 0.013 g x cm(-2) for piroxicam and tenoxicam, respectively. The potentiometric method involves the direct titration of both drugs with N-bromosuccinimide in acid medium and the end point is determined potentiometrically using platinum indicator electrode. Piroxicam and tenoxicam can be determined quantitatively in the concentration range of 0.33-3.37 and 0.33-4.08 mg x ml(-1) for tenoxicam and piroxicam, respectively. The standard deviation and relative standard deviation values are found to be ranged from 0.05-0.07 and 0.37-0.98% and 0.025-0.078 and 0.25-1.2% for tenoxicam and piroxicam, respectively. The two methods are accurate within +/-1.0%. Optimum conditions affecting both methods are studied. The proposed methods are applied for the determination of the drugs in pure form and in commercial pharmaceutical preparations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect flow-injection spectrophotometric determination of meloxicam, tenoxicam and piroxicam in pharmaceutical formulations.

A simple and sensitive indirect spectrophotometric method for the assay of meloxicam (MX), tenoxicam (TX) and piroxicam (PX) in pure and in pharmaceutical formulations by flow injection analysis (FIA) has been proposed. The method is based on the oxidation of these drugs by a known excess of N-bromosuccinimide (NBS) in an acidic medium, followed by a reaction of excess oxidant with chloranilic ...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Simultaneous spectrophotometric determination of lidocaine and hydrocortisone acetate in pharmaceutical preparations by multivariate calibration methods

The multivariate calibration method, partial least square regression (PLS) was applied for thesimultaneous spectrophotometric determination of Lidocaine (LID) and Hydrocortisone acetate(HCA) in their mixtures. The parameters of chemometric technique were optimized and theproposed method was validated with synthetic samples and applied to analyze these drugs inpharmaceutical products with good a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical & pharmaceutical bulletin

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2003