Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic postmenopausal women using a new multisite quantitative ultrasound device.

نویسندگان

  • John Damilakis
  • George Papadokostakis
  • Hrisanthi Vrahoriti
  • Ioanna Tsagaraki
  • Kostas Perisinakis
  • Alexander Hadjipavlou
  • Nicholas Gourtsoyiannis
چکیده

RATIONALE AND OBJECTIVES To assess a new multisite quantitative ultrasound (QUS) device (Sunlight Omnisense 7000 S) suitable for the measurement of speed of sound (SOS) in the phalanges, radius, and tibia. METHODS The study group consisted of 270 healthy Caucasian postmenopausal patients (mean age: 60.0 +/- 7.6 years) and 53 Caucasian postmenopausal patients (mean age: 67.2 +/- 7.4 years) with osteoporotic fractures. Measurements of SOS and bone mineral density (BMD) were carried out in all subjects. RESULTS Intraobserver in vivo short-term precision was on average 0.76% for the radius, 0.47% for the tibia, and 1.54% for the phalanges. The interobserver precision ranged from 0.77% to 2.39%. Measurements of SOS at the 3 skeletal sites were significantly correlated (r = 0.28-0.44; P < 0.001). Significant correlations were found between SOS at all sites and BMD (r = 0.21-0.41; P < 0.001). The odds ratio for fracture prediction for SOS was 1.47 for tibia, 1.69 for radius, and 2.69 for phalanx. The corresponding odds ratios for BMD at the lumbar spine, femoral neck, and total hip ranged from 2.08 to 3.26. The area under the receiver operating characteristic curve ranged from 0.611 to 0.741 for SOS measurements and from 0.745 to 0.797 for BMD measurements. CONCLUSIONS The Omnisense multisite QUS device exhibits reproducible performance. Among the QUS variables, the phalangeal SOS provides the best discrimination of fracture patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring Response to Osteoporosis Therapy with Alendronate by a Multisite Ultrasound Device

Background: Osteoporotic fractures are a major health problem among postmenopausal women. A significant proportion of subjects with low bone density are currently undiagnosed. Peripheral devices can be used for osteoporosis diagnosis, but their role in long-term monitoring of skeletal changes is unclear. The current study evaluated the ability of quantitative ultrasound (QUS) measurements to fo...

متن کامل

Panoramic-based mandibular indices in relation to mandibular bone mineral density and skeletal status assessed by dual energy X-ray absorptiometry and quantitative ultrasound.

OBJECTIVES The panoramic-based indices (Mandibular Cortical Index-MCI, the height of mandibular inferior cortex-IC (mm), Panoramic Mandibular Index-PMI, Mandibular Ratio-MR) were used to evaluate their diagnostic efficacy and to determine whether they correlate with bone mineral density (BMD (g/cm(2))) of the mandible and hip, and with ultrasound parameters of the calcaneus and hand phalanges i...

متن کامل

Monitoring response to osteoporosis therapy with alendronate by a multisite ultrasound device: a prospective study.

BACKGROUND Osteoporotic fractures are a major health problem among postmenopausal women. A significant proportion of subjects with low bone density are currently undiagnosed. Peripheral devices can be used for osteoporosis diagnosis, but their role in long-term monitoring of skeletal changes is unclear. The current study evaluated the ability of quantitative ultrasound (QUS) measurements to fol...

متن کامل

The application of discriminant analysis in differentiation of fibroadenoma and ductal carcinoma of breast tissue using ultrasound velocity measurement

Background: Ultrasound propagation velocity was measured experimentally in normal, fibroadenoma and ductal carcinoma breast tissues, in order to distinguish normal breast tissue from tumors. Materials and methods: In quantitative measurements of ultrasound velocity, 403 breast tissue images were selected, comprising 130 normal breast tissue, 130 fibroadenoma, and 143 ductal carcinoma tumors. Th...

متن کامل

مقایسه‌ شاخص‌های پایداری ایستا در زنان سالم، استئوپنیک و استئوپروتیک با استفاده از نوسان مرکز فشار(Center Of Pressure)

Objective: Change of control strategy in osteoporotic people and their focus on the hip strategy, also the occurred postural changes, result in the displacement of center of pressure (COP). This study was carried out to compare the static stability parameters in healthy, osteopenic and osteoporotic women. Methods: Seventy-one volunteer postmenopausal women aged 48-65 years were divided into th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 2003