Continuous fiberoptic arterial and venous blood gas monitoring in hemorrhagic shock.

نویسندگان

  • J M Oropello
  • A Manasia
  • E Hannon
  • A Leibowitz
  • E Benjamin
چکیده

STUDY OBJECTIVE To compare the performance of continuous fiberoptic blood gas monitoring with standard, intermittent blood gas sampling in the measurement of arterial and central venous blood gases during marked hemodynamic changes. DESIGN Prospective, consecutive, enrollment, experimental study. SETTING Research laboratory at a university medical center. PARTICIPANTS Seven anesthetized, mechanically ventilated pigs. INTERVENTIONS Severe shock was induced by hemorrhage in pigs monitored by a pulmonary artery catheter, an arterial line, and two fiberoptic blood gas sensors: one intra-arterial, and the other inserted into the superior vena cava via right internal jugular vein cutdown. Fiberoptic blood gas monitor measurements were compared with standard intermittent blood gas sampling. MEASUREMENTS AND RESULTS A total of 184 blood gas samples were compared in seven animals at baseline, during shock, and after resuscitation. The baseline mean (+/- 1 SD) cardiac output decreased from 4.0 +/- 0.9 to 1.2 +/- 0.6 L/min during shock and returned to baseline after retransfusion (3.9 +/- 1.3 L/min). The comparison of continuous fiberoptic blood gas monitoring with intermittent blood gas sampling showed a bias+/-precision of 0.035 +/- 0.047 for arterial pH, 0.021 +/- 0.031 for central venous pH, -4.09 +/- 2.96 mm Hg (-0.55 +/- 0.39 kPa) for arterial Pco2, -3.67 +/- 2.44 mm Hg (-0.49 +/- 0.3 3 kPa) for central venous Pco2, -5.79 +/- 9.64 mm Hg (-0.77 +/- 1.29 kPa) for arterial Po2, and -7.85 +/- 8.52 mm Hg (-1.05 +/- 1.14 kPa) for central venous Po2. CONCLUSIONS Continuous fiberoptic blood gas monitoring agrees closely with standard intermittent blood gas sampling during severe hemodynamic shifts and has a comparable accuracy for both arterial and venous blood gas measurements. Changes in venous Pco2 have recently been shown to correlate with changes in global tissue perfusion (eg, changes in cardiac output). Such data, available immediately via continuous venous blood gas monitoring, may be useful for monitoring shock and the response to resuscitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Esophageal capnometry during hemorrhagic shock and after resuscitation in rats

BACKGROUND Splanchnic perfusion following hypovolemic shock is an important marker of adequate resuscitation. We tested whether the gap between esophageal partial carbon dioxide tension (PeCO2) and arterial partial carbon dioxide tension (PaCO2) is increased during graded hemorrhagic hypotension and reversed after blood reinfusion, using a fiberoptic carbon dioxide sensor. MATERIALS AND METHO...

متن کامل

Effects of environmental hypothermia on hemodynamics and oxygen dynamics in a conscious swine model of hemorrhagic shock.

BACKGROUND Hypothermia is associated with poor outcome in trauma patients; however, hemorrhagic shock (HS) model with anesthetized swine was different from that of clinical reality. To identify the effects of environmental hypothermia on HS, we investigated hemodynamics and oxygen dynamics in an unanesthetized swine model of HS under simulating hypothermia environment. METHODS Totally 16 Bama...

متن کامل

Effect of ATP-MgCl2-hypertonic solution (NaCl5%) administration on hemorrhagic shock

Introduction: In the recent years, effect of hypertonic solution in resuscitation of shock has been shown by clinical and laboratory studies. On the other hand ATP-MgCl2 is used for better tissue perfusion and cardiac output in shock. The aim of this study is evaluation of ATP-MgCl2 with hypertonic solution in resuscitation of hemorrhagic shock. Materials and Methods: In this experimental stud...

متن کامل

A technique for continuous bedside monitoring of global cerebral energy state

BACKGROUND Cerebral cytoplasmatic redox state is a sensitive indicator of cerebral oxidative metabolism and is conventionally evaluated from the extracellular lactate/pyruvate (LP) ratio. In the present experimental study of global cerebral ischemia induced by hemorrhagic shock, we investigate whether the LP ratio obtained from microdialysis of cerebral venous blood may be used as a surrogate m...

متن کامل

Monitoring Microcirculatory Blood Flow with a New Sublingual Tonometer in a Porcine Model of Hemorrhagic Shock

Tissue capnometry may be suitable for the indirect evaluation of regional hypoperfusion. We tested the performance of a new sublingual capillary tonometer in experimental hemorrhage. Thirty-six anesthetized, ventilated mini pigs were divided into sham-operated (n = 9) and shock groups (n = 27). Hemorrhagic shock was induced by reducing mean arterial pressure (MAP) to 40 mmHg for 60 min, after w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 109 4  شماره 

صفحات  -

تاریخ انتشار 1996