A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging

نویسندگان

  • Zahra Dalili Kajan
  • Jalil Khademi
  • Ahmad Alizadeh
  • Yasamin Babaei Hemmaty
  • Zahra Atrkar Roushan
چکیده

PURPOSE This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. MATERIALS AND METHODS A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1 -weighted images, fast spin-echo T2 -weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. RESULTS Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. CONCLUSION With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Magnetic resonance imaging artefacts and fixed orthodontic attachments].

OBJECTIVES Orthodontic appliances are often removed before magnetic resonance imaging (MRI) scans because they are known to produce artefacts. The purpose of this study was to find the exact indications for removal of various fixed attachments when imaging four specific areas of the head and neck. MATERIALS AND METHODS Sixty patients requiring an MRI scan of the head for medical reasons volun...

متن کامل

Magnetic resonance imaging metal artifact reduction for eye plaque patient with dental braces

Purpose To determine if metal artifact reduction can minimize magnetic susceptibility artifacts in the orbits for an eye plaque brachytherapy patient with metallic dental braces. Material and methods A 62-year-old female patient with a choroidal melanoma in the right eye received a 1.5 T magnetic resonance imaging (MRI) simulation for 3D eye plaque brachytherapy planning. The protocol include...

متن کامل

Influence of orthodontic appliance-derived artifacts on 3-T MRI movies

BACKGROUND Magnetic resonance imaging (MRI) has been used to study configurations of speech organs in the resting state. However, MRI is sensitive to metals, and numerous types of metallic appliances, most of which have a large magnetic susceptibility, are used in orthodontic treatment and may cause severe artifacts on MRI. We have developed techniques for obtaining MRI movies of the oral regio...

متن کامل

Artifacts in brain magnetic resonance imaging due to metallic dental objects.

OBJECTIVE Artifacts caused by metallic objects, such as dental crowns, dental implants and metallic orthodontic appliances, are a common problem in head and neck MRI. The aim of this retrospective study was to identify the main metal dental objects that produce artifacts on brain MRIs. STUDY DESIGN Imaged metallic artifacts and their sources were identified. Artifact image plane was rated on ...

متن کامل

تأثیر فرآیند بازیافت بر میزان آزاد سازی یون‌های فلزی از براکت‌های ارتودنسی در زمان‌های مختلف

Background and Aims: Considering the application of recycled metallic brackets in orthodontic treatments and probably more resultant metal ion release, which can cause cytotoxic side effects, this study was set up to assess the effect of recycling process of orthodontic brackets on metal ion release.Materials and Methods: In this experimental study, 80 Discovery direct bond brackets (Dentarum, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2015