Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry

نویسندگان

  • I.C.N. Sacco
  • A.P. Picon
  • A.P. Ribeiro
  • C.D. Sartor
  • F. Camargo-Junior
  • D.O. Macedo
  • E.T.T. Mori
  • F. Monte
  • G.Y. Yamate
  • J.G. Neves
  • V.E. Kondo
  • S. Aliberti
چکیده

The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rock mass structural characterization via short-range digital photogrammetry

Because of the important role of rock mass structural properties on its mechanical behavior, determining the qualitative and quantitative properties of has been a subject of intense research. In this regard, numerous techniques such as scanline surveying, cell mapping, and geologic structure mapping have been proposed. However, applying such field surveying techniques for rock mass properties i...

متن کامل

Digital surface model extraction with high details using single high resolution satellite image and SRTM global DEM based on deep learning

The digital surface model (DSM) is an important product in the field of photogrammetry and remote sensing and has variety of applications in this field. Existed techniques require more than one image for DSM extraction and in this paper it is tried to investigate and analyze the probability of DSM extraction from a single satellite image. In this regard, an algorithm based on deep convolutional...

متن کامل

Analysis of angular reading distortions of photographic images Análise das distorções em leituras angulares de imagens fotográficas

Background: Although photogrammetry is a widespread technique in the health field, despite of the methodological efforts distortions in the angular readings of the images are common. Objective: To measure the error of angular measurements in photo images with different digital resolutions in an object with pre-determined angles. Method: We used a rubber ball with 52 cm in circumference. The obj...

متن کامل

Investigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT

Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...

متن کامل

Foot placement angle and arch type: effect on rearfoot motion.

The purpose of the study was to describe the relationship between foot placement angle, arch type, and rearfoot motion during running. Twenty women were filmed in the frontal plane at 100 fps. Subjects displaying a variety of foot placement angles were chosen. Before data collection, arch indices were calculated. Each subject ran five trials at a pace of 3.5 m/sec. All subjects wore the same ty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2012