Experimental Investigations into Frost Formation on Display Cabinet Evaporators in Order to Implement Defrost on Demand

نویسندگان

  • D. Datta
  • S. A. Tassou
  • D. Marriott
  • D Datta
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frost Prediction on Evaporator Coils of Supermarket Display Cabinets Using Artificial Neural Networks

Defrosting in supermarket refrigeration systems is normally controlled by a preset time cycle with most display cabinets timed to defrost every 6 hours. It is widely acknowledged that timed defrost may cause a number of unnecessary defrost cycles and this reduces the energy efficiency of refrigeration systems as well as the accuracy of temperature control of the cases. This paper investigates t...

متن کامل

Frost Formation on Fan-Supplied Tube-Fin Evaporators: A Visual and Numerical Analysis

This paper presents an experimental and numerical study to evaluate the thermal-hydraulic performance of light commercial capacity evaporators operating under frosting conditions. A tube-fin heat exchanger was tested on a closed-loop wind-tunnel considering the fan performance. A visual analysis of the frost formation processes was carried out to compare the frost layer morphology in different ...

متن کامل

Experimental Evaluation Of The Frost Formation

Frost formation on an evaporator causes significant problems by decreasing inlet air flow. It is important for a precise prediction to understand the dominant factor of the frost formation. In this paper, the frost layer on the cold plate is experimentally obtained with different velocities while maintaining a surface temperature at -20 degrees Celsius. The mass and height of the frost layer is...

متن کامل

Air-side heat transfer enhancement of a refrigerator evaporator using vortex generation

In most domestic and commercial refrigeration systems, frost forms on the air-side surface of the air-to-refrigerant heat exchanger. Frost-tolerant designs typically employ a large fin spacing in order to delay the need for a defrost cycle. Unfortunately, this approach does not allow for a very high air-side heat transfer coefficient, and the performance of these heat exchangers is often air-si...

متن کامل

A New Dynamic Heat Exchanger Model with Frosting and Defrosting

In this paper, a dynamic heat exchanger model that unifies the frosting and defrosting analyses is presented. A novel scheme is proposed to solve the air flow redistribution due to non-uniform frost blockage. Unlike the existing defrost models which separate analysis for tubes and fins, the proposed defrost model unifies the analysis to maintain model consistency. The first-principles based fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014