Extended depth of focus contact lenses vs. two commercial multifocals: Part 2. Visual performance after 1 week of lens wear

نویسندگان

  • Ravi C. Bakaraju
  • Daniel Tilia
  • Jennifer Sha
  • Jennie Diec
  • Jiyoon Chung
  • Danny Kho
  • Shona Delaney
  • Anna Munro
  • Varghese Thomas
چکیده

PURPOSE To compare the visual performance of prototype contact lenses designed via deliberate manipulation of higher-order spherical aberrations to extend-depth-of-focus with two commercial multifocals, after 1 week of lens wear. METHODS In a prospective, participant-masked, cross-over, randomized, 1-week dispensing clinical-trial, 43 presbyopes [age: 42-63 years] each wore AIROPTIX Aqua multifocal (AOMF), ACUVUE OASYS for presbyopia (AOP) and extended-depth-of-focus prototypes (EDOF) appropriate to their add requirements. Measurements comprised high-contrast-visual-acuity (HCVA) at 6m, 70cm, 50cm and 40cm; low-contrast-visual-acuity (LCVA) and contrast-sensitivity (CS) at 6m and stereopsis at 40cm. A self-administered questionnaire on a numeric-rating-scale (1-10) assessed subjective visual performance comprising clarity-of-vision and lack-of-ghosting at various distances during day/night-viewing conditions and overall-vision-satisfaction. RESULTS EDOF was significantly better than AOMF and AOP for HCVA averaged across distances (p≤0.038); significantly worse than AOMF for LCVA (p=0.021) and significantly worse than AOMF for CS in medium and high add-groups (p=0.006). None of these differences were clinically significant (≤2 letters). EDOF was significantly better than AOMF and AOP for mean stereoacuity (36 and 13 seconds-of-arc, respectively: p≤0.05). For clarity-of-vision, EDOF was significantly better than AOP at all distances and AOMF at intermediate and near (p≤0.028). For lack-of-ghosting averaged across distances, EDOF was significantly better than AOP (p<0.001) but not AOMF (p=0.186). EDOF was significantly better than AOMF and AOP for overall-vision-satisfaction (p≤0.024). CONCLUSIONS EDOF provides better intermediate and near vision performance than either AOMF or AOP with no difference for distance vision after 1 week of lens wear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics

PURPOSE To compare the computed optical performance of prototype lenses designed using deliberate manipulation of higher-order spherical aberrations to extend depth-of-focus (EDOF) with two commercial multifocals. METHODS Emmetropic, presbyopic, schematic eyes were coupled with prototype EDOF and commercial multifocal lenses (Acuvue Oasys for presbyopia, AOP, Johnson & Johnson & Air Optix Aqu...

متن کامل

Corneal swelling response to contact lenses worn under extended wear conditions.

Corneal thickness changes were monitored in ten subjects (1) over a 36-hour period without contact lens wear and (2) during 7 days continuous wear of three types of hydrogel contact lenses of different back vertex powers. Measured on awakening, the mean overnight central corneal edema without lenses was 3.0% ± 1.2%. With the lenses used in this study, the mean overnight corneal swelling over th...

متن کامل

Selective binding of a 30-kilodalton protein to disposable hydrophilic contact lenses.

To investigate the accumulation of tear proteins on disposable extended-wear contact lenses (42% Etafilcon A and 58% hydration), a technique involving sodium dodecyl sulfate-polyacrylamide minigel electrophoresis combined with a sensitive silver-staining method was used. Besides the binding of large amounts of tear lysozyme the authors found an accumulation of an as yet unidentified 30-kilodalt...

متن کامل

Clinical Study of Focus IGHT & DAY ® contact lenses

Objectives To investigate the visual and ocular implications of continuous wearing a silicon hydrogel contact lens for up to 3 weeks , in a dry semi-arid climate environment. Methods Clinical examination of eye conditions (visual acuity, Schirmer test, corneal thickness and endothelial cells counts) for 9 healthy voluntary students was carried out between September and November of 2004 in Riyad...

متن کامل

Corneal and conjunctival sensory function: the impact on ocular surface sensitivity of change from low to high oxygen transmissibility contact lenses.

PURPOSE Deprivation of oxygen to the ocular surface during contact lens wear has been implicated in the alteration of sensory function. This study investigates whether increasing oxygen availability through discontinuation of contact lens wear or transfer into highly oxygen transmissible (high Dk/t) lenses leads to a change in corneal or conjunctival sensitivity. METHODS Twenty-seven long-ter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2018