Ranking of line outages in an AC-DC system causing overload and voltage problems

نویسندگان

  • P. R. Bijwe
  • J. Nanda
  • K. L. Puttabuddhi
چکیده

In the paper an efficient noniterative method for ranking line outage contingencies in an AC-DC system based on overload and voltage deviation performance indices is developed. The method is based on the calculation of complex line outage current compensations using a coupled AC-DC load flow Jacobian matrix. The proposed method is further extended for the calculation of line outage distribution factors which could be very useful for reducing the computational burden in security constrained optimisation problems. A mathematical model for handling bus-type switching resulting from reactive power limit violations is also developed. Results for a modified IEEE 14-bus system have been obtained with the proposed method and are compared with those obtained by rigorous AC-DC load flow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-Stage DC-AC Converter Based on new DC-DC converter for energy conversion

This paper proposes a multi-stage power generation system suitable for renewable energy sources, which is composed of a DC-DC power converter and a three-phase inverter. The DC-DC power converter is a boost converter to convert the output voltage of the DC source into two voltage sources. The DC-DC converter has two switches operates like a continuous conduction mode. The input current of DC-DC...

متن کامل

Controlling Both the DC Boost and AC Output Voltage of Z-Source Inverter Using Neural Network Controller with Minimization of Voltage Stress Across Devices

This paper presents a method to control both the dc boost and the ac output voltage of Z-source inverter using neural network controllers. The capacitor voltage of Z-source network has been controlled linearly in order to improve the transient response of the dc boost control of the Z-source inverter. The peak value of the line to line ac output voltage is used to control and keep the ac output...

متن کامل

Stability Analysis in Parametrically Excited Electrostatic Torsional Micro-actuators

This paper addresses the static and dynamic stabilities of a parametrically excited torsional micro-actuator. The system is composed of a rectangular micro-mirror symmetrically suspended between two electrodes and acted upon by a steady (dc ) while simultaneously superimposed to an (ac ) voltage. First, the stability of the system subjected to a quasi-statically applied (dc ) voltage is investi...

متن کامل

BIC based on Modified Droop Control of Hybrid AC/DC Microgrid with PV/Wind/ESS under Variable Generation and Load Conditions

The idea of a microgrid is created by utilizing more diverse ac or dc distributed generation (DG) sources along with an energy storage system (ESS) and loads. The most efficient and reliable selection of ac and dc microgrids is a hybrid ac/dc microgrid. The hybrid microgrid largely overcomes the shortcomings of standalone ac or dc microgrids. A bidirectional interlinking converter (BIC) is util...

متن کامل

A Novel Control Strategy for a Single-phase Grid-connected Power Injection System

In this paper, a novel and simple control strategy, based on state feedback method is suggested to control the power injection system (PIS). The considered PIS is composed of, a DC voltage source, a voltage source inverter (VSI) and a L-C-L filter. The DC source includes the battery source with boosted voltage. The battery can be charged with photovoltaic cells. Since, the grid voltage acts as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006