Near- and Far-field Measurements of Strip Conductor-type Coils for 7-tesla Mri

نویسندگان

  • K. Solbach
  • S. Orzada
  • P. Yazdanbakhsh
چکیده

Introduction: We have realized strip conductor-type coils for 7-Tesla MRI based on two design concepts, the dipoleand the loop-configuration. However, both types have shown unconventional characteristics, in particular the figure-of-merit of “unloaded” Q-factor over “loaded” Q-factor and its dependence on the distance from a phantom, see our companion abstract/1/. In order to learn more about the inherent properties of the coil designs, we performed measurements of the magnetic and electric near-field in free space around the coils as well as far-field radiation measurements. Methods: Our dipole-type, Fig.1(above), has been used successfully in an 8-element circular array configuration /2/. This design is a true half-wavelength dipole with 60% of the length of each arm folded in a meander to reduce the total length to 25 cm. The dipole is fed symmetrically at the centre and is elevated above a 10 cm wide reflector plate by 20 mm. The currents in the reflector plate are excited by (parasitic) electromagnetic coupling, contrary to the ground plane current in the loop-type coil of Fig.1(below), an off-center feed adaptation of /3/with about 30 cm length by 10 cm width, where the current flows continuously through the end capacitors into the ground plane (hence “loop”-type coil). Near-field measurements were performed in our anechoic chamber with the coil fixed on a table which can be moved horizontally on a rail and with a field probe fixed to a precision vertical slide, Fig.2. By setting-up the coil with the strip conductor in vertical direction we did longitudinal cuts while transverse cuts were done by rotating the coil and the probe (polarization!) by 90°. Cuts in different levels (distances) above the coil were produced by moving the table along the rail. Any absorbing or dense material was placed far away from the coil in order not to load or distort the coil fields, yet it was found necessary to have an absorbing environment in order to achieve repeatable measurements with a low level of measurement range artifacts (caused by radiation). The probe for B1 magnetic flux, Fig.3, is based on the conventional loop design with slotted electric shield – improved by a compensation of the loop E-field pick-up sensitivity. The probe for the electric field was a short dipole fed symmetrically by a coaxial half-wave balun. By measuring the complex coupling coefficients between the coils and the probes as a function of position using a Vector Network Analyzer, we were able to compare field distributions of different coils without the need for absolute probe calibration. The far-field measurements were done in our microwave anechoic chamber using a transmitting antenna at the end of the chamber and the coil as receiving antenna positioned on a rotating table 5 meters apart at the other end. Since the absorber lining of the chamber walls is not well suited for frequencies much below 1 GHz, artifacts have been observed in the measured patterns; therefore, we also did verification measurements in free space on the roof of our building, Fig.4 which gave reasonable agreement in gain and pattern measurements. Results: The far-field patterns of the two coil types are shown in Fig.5: The dipole exhibits deep minima in axial direction, as required due to the lack of transverse current flow. Contrary to that, the loop exhibits strong fields in axial direction which can be attributed to the transverse currents through the capacitors at the strip conductor ends. We also see that the dipole has its maximum radiation into the backward direction which proves that the reflector plate acts as a “director” of a YagiUda array, while the coil produces its main beam in forward direction (the ground plane is a true “reflector”). However, both coils exhibit only a small forward-tobackward ratio which is a clear indicator that the size of reflector plane or ground plane is electrically small (only lambda/4). The absolute gain was measured by the comparison method using a reference standard dipole antenna and was found around 0 dBi for the dipole and about 2 dBi for the loop which is only a few dB below the gain expected from a conventional quarter-wave antenna.The longitudinal cut measurements of magnetic flux at close distance of 20 mm above the conductor strip, Fig.6(upper), show that the current magnitudes are 3 dB apart with similar distributions along the strip conductor ( both types with two mild current maxima offset from the centre). However, as shown in Fig.6(middle), at a larger distance of 100 mm, the resulting magnetic flux of the dipole is 6 dB larger compared to the loop-type. However, the loop spreads the magnetic flux over a wider area which can also be observed in the transversal cut patterns, Fig.6(lowest). In dead, further measurements of fields at the sides of the coils prove that the main flux of the loop-type coil is close to the plane normal to the loop-plane and containing the strip conductor; this seems to be the reason for the observed strong mutual coupling of two loop-type coils side by side of about -4 to -5 dB while we measure only -13 dB for two dipole-type coils. A comparison of electric field strength of the two coil types shows quite non-uniform field distributions close to the conductor strips, but at larger distance of 100 mm, Fig.7, we observe very low levels of E-field directly above the dipole with higher levels close to the dipole open ends; the loop-type

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo multiple-mouse MRI at 7 Tesla.

We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost ar...

متن کامل

Optimization of Internal MRI Coils Using Ultimate Intrinsic SNR

Introduction Internal coils are widely used in MRI applications for both diagnostic and interventional studies [1]. Their high SNR characteristics make them more preferable in certain applications when compared to conventil external coils. Although many studies exist for the optimization of external coils to obtain increased SNR, an optimization study for internal MRI coils can also be made. In...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Evaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009