Temporal Treatment of a Thermal Response for Defect Depth Estimation

نویسندگان

  • Y. A. Plotnikov
  • W. P. Winfree
چکیده

Transient thermography, which employs pulse surface heating of an inspected component followed by acquisition of the thermal decay stage, is gaining wider acceptance as a result of its remoteness and rapidness. Flaws in the component’s material may induce a thermal contrast in surface thermograms. An important issue in transient thermography is estimating the depth of a subsurface flaw from the thermal response. This improves the quantitative ability of the thermal evaluation: from one scan it is possible to locate regions of anomalies in thickness (caused by corrosion) and estimate the implications of the flaw on the integrity of the structure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Subsurface Defect Evaluation by Pulsed Phase Thermography : Depth Retrieval with the Phase

Pulsed Phase Thermography (PPT) is a NonDestructive Testing and Evaluation (NDT&E) technique based on the Fourier Transform that can be thought as being the link between Pulsed Thermography, for which data acquisition is fast and simple; and Lock-In thermography, for which depth retrieval is straightforward. A new depth inversion technique using the phase obtained by PPT is proposed. The techni...

متن کامل

Depth of anesthesia estimation based on EEG signal using brain effective connectivity between frontal and temporal regions

Background: Ensuring adequate depth of anesthesia during surgery is essential for anesthesiologists to prevent the occurrence of unwanted alertness during surgery or failure to return to consciousness. Since the purpose of using anesthetics is to affect the central nervous system, brain signal processing such as electroencephalography (EEG) can be used to predict different levels of anesthesia....

متن کامل

Assessment of Anesthesia Depth Using Effective Brain Connectivity Based on Transfer Entropy on EEG Signal

Introduction: Ensuring an adequate Depth of Anesthesia (DOA) during surgery is essential for anesthesiologists. Since the effect of anesthetic drugs is on the central nervous system, brain signals such as Electroencephalogram (EEG) can be used for DOA estimation. Anesthesia can interfere among brain regions, so the relationship among different areas can be a key factor in the anesthetic process...

متن کامل

Non-destructive Evaluation of Composites Materials by Pulsed-phase Thermography: Depth Inversion

This work is focused in the application of Pulsed-Phase Thermography (PPT) to non-destructive evaluation of composite materials. In this approach, the composite sample is heated by a thermal pulse briefly and recording the surface temperature decay with an infrared camera. Data processing and depth inversion is carried out by extracting and analyzing the response of the sample on the frequency ...

متن کامل

NEW APPLICATION FOR THE BITEMPORAL (VISOR) FLAP IN RECONSTRUCTION OF ADVANCED LOWER LIP CARCINOMA

Background: Lip carcinoma is a common cancer with a good prognosis and when patients refer early in the course of disease the results of treatment are acceptable. Surgical procedures for reconstruction of lip defects are the use of remaining lip tissue, tissue from the opposite lip, adjacent cheek tissue, distant flaps and microvascular free flaps. The bitemporal (visor) flap is a regional...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999