Germanium Orthogonal Strip Detectors with Amorphous-Semiconductor Contacts

نویسندگان

  • P. N. Luke
  • M. Amman
  • B. F. Phlips
  • W. N. Johnson
  • R. A. Kroeger
چکیده

Germanium orthogonal strip detectors have been produced using amorphous-semiconductor contacts. The amorphoussemiconductor contact fabrication process is relatively simple, and it is capable of producing fine-pitched electrode structures. The bipolar blocking behavior of the amorphoussemiconductor contact permits its use on both sides of a detector, replacing conventional B ion implanted and Li diffused contacts. A 5 × 5 orthogonal strip detector has been produced using this technique. Experimental results from this detector are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy

Gamma-ray imaging with position-sensitive germanium detectors offers the advantages of excellent energy resolution, high detection efficiency, and potentially good spatial resolution. The development of the amorphous-semiconductor electrical contact technology for germanium detectors has simplified the production of these position-sensitive detectors and has made possible the use of unique dete...

متن کامل

Position Sensitive Germanium Detectors for the Advanced Compton Telescope

The nuclear line region of the gamma ray spectrum remains one of the most challenging and elusive goals of high energy astrophysics. The scientific objectives are well defined, but require well over a factor of 10 increase in sensitivity compared to present day instruments to be achieved. The most promising approach to achieve this sensitivity and a broad range of scientific objectives is offer...

متن کامل

Development of Germanium Strip Detectors for Environmental Remediation1

We present the initial results of the first germanium strip detector array for the imaging and high-resolution spectroscopy of gamma-ray sources. The array consists of four detectors, 5 x 5 x 1 cm each with 25 strips on each side. The detectors are daisy-chained to hybrid preamplifiers to reduce the number of channels of electronics. Good spectroscopy and imaging are achieved. We also present r...

متن کامل

New Contact Development for Si(Li) Orthogonal-Strip Detectors

At present, the contacts generally used for lithium-drifted silicon detectors consist of a diffused lithium layer (n-type) and a gold surface barrier (p-type). These contacts work well for unsegmented detectors. However, they both have disadvantages if used for segmented detectors. For this reason, we are developing new types of contacts that will be more robust and easier to segment. To replac...

متن کامل

Spatial Resolution and Imaging of Gamma-Rays with Germanium Strip Detectors

Germanium strip detectors combine high quality spectral resolution with two-dimensional positioning of -ray interactions. Readout is accomplished using crossed electrodes on opposite faces of a planar germaniumdetector. Potential astrophysics applications include focal plane detectors for coded-aperture or grazing incidence X-ray mirror imagers, and as detection elements of a high resolution Co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999