Rotational Stability of Monofocal and Trifocal Intraocular Toric Lenses With Identical Design and Material but Different Surface Treatment.

نویسنده

  • Kristof Vandekerckhove
چکیده

PURPOSE To compare the rotational stability, total misalignment, and visual and refractive outcomes achieved with a trifocal toric versus a monofocal toric intraocular lens (IOL). METHODS In this prospective, interventional case series, eyes of patients consecutively scheduled for cataract surgery who had clinically relevant astigmatism were implanted with a FineVision Pod FT trifocal toric IOL or an Ankoris monofocal toric IOL (both PhysIOL SA, Liège, Belgium). Certain comorbidities, such as pseudoexfoliation syndrome, were allowed. IOL rotation and total misalignment were analyzed 15 minutes, 1 day, 1 week, 6 weeks, 6 months, and 1 year postoperatively. RESULTS Seventy-one eyes of 53 patients were assessed: 37 eyes were implanted with the trifocal IOL and 34 eyes with the monofocal IOL. More IOL rotation occurred in the monofocal group compared to the trifocal group (mean 4.23° ± 4.64° vs 2.55° ± 2.62°; P = .043, 12 months). Mean total misalignment was higher in the monofocal group (6.67° ± 6.59° at 12 months vs 3.79° ± 3.59° in the trifocal group) (P = .017). Postoperatively, more eyes achieved a refractive cylinder of 0.50 diopters or below in the trifocal group (65% at 12 months) than in the monofocal group, even in the monofocal subgroup analysis that excluded keratoconic eyes (42% at 12 months; P = .009). CONCLUSIONS The monofocal and trifocal toric IOLs both appear to effectively reduce refractive astigmatism and provide good visual acuity in astigmatic patients having cataract surgery. The trifocal toric IOL offers better rotational stability than the monofocal IOL, probably due to the higher frictional coefficient of its surface. [J Refract Surg. 2018;34(2):84-91.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.

PURPOSE To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). METHODS A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin...

متن کامل

Laboratory Evaluation of the Influence of Decentration and Pupil Size on the Optical Performance of a Monofocal, Bifocal, and Trifocal Intraocular Lens.

PURPOSE To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing. METHODS Using an optical bench set-up, an aspheric monofocal (CT ASPHINA 409M; Carl Zeiss Meditec, Jena, Germany), an aspheric diffractive bifocal (AT LISA 809M; Carl Ze...

متن کامل

Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.

PURPOSE To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs. SETTING Private practice, Los Altos, California, USA. METHODS One hundred consecutive eyes with an AcrySof SN60T(3, 4, or 5) toric IOL were compared with a consecutive series of 90 AA4203 (TL or TF) toric IOLs. The same su...

متن کامل

Refractive and Visual Outcomes of Different Intraocular Lenses with Femtosecond Laser Cataract Surgery: The Expectation of Independence from Spectacles

PURPOSE To evaluate the visual performance of different types of intraocular lens (IOL) in eyes submitted to femtosecond laser (FSL) cataract surgery and to analyze whether this technology could result in spectacles independence. DESIGN Retrospective comparative case series. METHODS Consecutive eyes that were scheduled for FSL cataract surgery were included in this study. After one month po...

متن کامل

In vitro optical quality measurements of three intraocular lens models having identical platform

BACKGROUND With recent advances in technology and introduction of new intraocular lens (IOL) models, surgeons today have the opportunity to choose from various optical designs, which can influence the postoperative quality of vision. In our laboratory study, we compared the optical quality of three different IOLs that use the identical platform and are produced by the same manufacturer. The stu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 2018