Three-dimensional (3D) information on blood flow and vessel morphology is important when assessing cerebrovascular disease and when monitoring interventions. Rotational angiography is nowadays routinely used to determine the geometry of the cerebral vasculature. To this end, contrast agent is injected into one of the supplying arteries and the x-ray system rotates around the head of the patient while it acquires a sequence of x-ray images. Besides information on the 3D geometry, this sequence also contains information on blood flow, as it is possible to observe how the contrast agent is transported by the blood. The main goal of this thesis is to exploit this information for the quantitative analysis of blood flow. I propose a model-based method, called flow map fitting, which determines the blood flow waveform and the mean volumetric flow rate in the large cerebral arteries. The method uses a model of contrast agent transport to determine the flow parameters from the spatio-temporal progression of the contrast agent concentration, represented by a flow map. Furthermore, it overcomes artefacts due to the rotation (overlapping vessels and foreshortened vessels at some projection angles) of the c-arm using a reliability map. For the flow quantification, small changes to the clinical protocol of rotational angiography are desirable. These, however, hamper the standard 3D reconstruction. Therefore, a new method for the 3D reconstruction of the vessel morphology which is tailored to this application is also presented. To the best of my knowledge, I have presented the first quantitative results for blood flow quantification from rotational angiography. Additionally, the model-based approach overcomes several problems which are known from flow quantification methods for planar angiography. The method was mainly validated on images from different phantom experiments. In most cases, the relative error was between 5% and 10% for the volumetric mean flow rate and between 10% and 15% for the blood flow waveform. Additionally, the applicability of the flow model

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood Flow and Velocity Estimation Based on Vessel Transit Time by Combining 2D and 3D X-Ray Angiography

The X-ray imaging equipment could be used to measure hemodynamic function in addition to visualizing the morphology. The parameters of specific interest are arterial blood flow and velocity. Current monoplane X-ray systems can perform 3D reconstruction of the arterial tree as well as to capture the propagation of the injected contrast agent on a sequence of 2D angiograms. We combine the 2D digi...

متن کامل

Using flow information to support 3D vessel reconstruction from rotational angiography.

For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information...

متن کامل

3D Diagnostic Imaging of Blood Vessels using an X-Ray Rotational Angiographic System

In this paper, we describe a prototype system that. reconstructs three-dimensional (3D) blood vessels image from cone-beam projection images and analyzes the 3D reconstructed image. Several 3D reconstruction methods utilize biplane or stereo angiographic system and assume the cross section shapes of blood vessels (e.g. ellipse). However, the information provided by a few projections is insuffic...

متن کامل

Clinical feasibility of a fully automated 3D reconstruction of rotational coronary X-ray angiograms.

BACKGROUND Although fixed view x-ray angiography remains the primary technique for anatomic imaging of coronary artery disease, the known shortcomings of 2D projection imaging may limit accurate 3D vessel and lesion definition and characterization. A recently developed method to create 3D images of the coronary arteries uses x-ray projection images acquired during a 180 degrees C-arm rotation a...

متن کامل

Estimating Continuous 4D Wall Motion of Cerebral Aneurysms from 3D Rotational Angiography

This paper presents a technique to recover dynamic 3D vascular morphology from a single 3D rotational X-ray angiography acquisition. The dynamic morphology corresponding to a canonical cardiac cycle is represented via a 4D B-spline based spatiotemporal deformation. Such deformation is estimated by simultaneously matching the forward projections of a sequence of the temporally deformed 3D refere...