Correcting for the influence of sampling conditions on biomarkers of exposure to phenols and phthalates: a 2-step standardization method based on regression residuals

نویسندگان

  • Marion Mortamais
  • Cécile Chevrier
  • Claire Philippat
  • Claire Petit
  • Antonia M Calafat
  • Xiaoyun Ye
  • Manori J Silva
  • Christian Brambilla
  • Marinus JC Eijkemans
  • Marie-Aline Charles
  • Sylvaine Cordier
  • Rémy Slama
چکیده

BACKGROUND Environmental epidemiology and biomonitoring studies typically rely on biological samples to assay the concentration of non-persistent exposure biomarkers. Between-participant variations in sampling conditions of these biological samples constitute a potential source of exposure misclassification. Few studies attempted to correct biomarker levels for this error. We aimed to assess the influence of sampling conditions on concentrations of urinary biomarkers of select phenols and phthalates, two widely-produced families of chemicals, and to standardize biomarker concentrations on sampling conditions. METHODS Urine samples were collected between 2002 and 2006 among 287 pregnant women from Eden and Pélagie cohorts, from which phthalates and phenols metabolites levels were assayed. We applied a 2-step standardization method based on regression residuals. First, the influence of sampling conditions (including sampling hour, duration of storage before freezing) and of creatinine levels on biomarker concentrations were characterized using adjusted linear regression models. In the second step, the model estimates were used to remove the variability in biomarker concentrations due to sampling conditions and to standardize concentrations as if all samples had been collected under the same conditions (e.g., same hour of urine collection). RESULTS Sampling hour was associated with concentrations of several exposure biomarkers. After standardization for sampling conditions, median concentrations differed by--38% for 2,5-dichlorophenol to +80 % for a metabolite of diisodecyl phthalate. However, at the individual level, standardized biomarker levels were strongly correlated (correlation coefficients above 0.80) with unstandardized measures. CONCLUSIONS Sampling conditions, such as sampling hour, should be systematically collected in biomarker-based studies, in particular when the biomarker half-life is short. The 2-step standardization method based on regression residuals that we proposed in order to limit the impact of heterogeneity in sampling conditions could be further tested in studies describing levels of biomarkers or their influence on health.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Developed Electromembrane Technique Based on Flat Electrospun Membrane Coupled with Gas-chromatography for the Determination of Phthalates in Different Water Samples

In this work, we successfully developed electromembrane extraction via preparation of an electrospun flat membrane based on device. The polyurethane-membrane was prepared by electrospinning method and used in EME. Affecting parameters on membrane preparation were optimized by Taguchi design. The developed method was used for extraction of phthalates as typical molecules and the proposed method ...

متن کامل

ارزیابی خطر سرطان‌زایی و غیر سرطان‌زایی مواجهه با استرهای فتالات از طریق مصرف آب‌های بطری شده در طول زمان نگهداری

Background and Objectives: Bottles for packaging drinking water represent one of the most popular uses of plastic and polymer additives. Recently, public concerns related to possibility of exposure to chemicals through the consumption of polyethylene terephthalate bottled water has caused great concern to consumers. Phthalate esters, as a class of these compounds, are often classified as endocr...

متن کامل

Diagnostic Biomarkers of Heat Stress Induced- DNA in Occupational Exposure: A Systematic Review

Introduction: Climate change and hot processes in the workplaces has led to an increase in the effects of heat stress on employed people, which has become a major concern, especially in tropical and subtropical countries. Early detection of biomarkers in induction of heat stress-related DNA damage can be used in the identification and evaluation of health and safety, including occupational heal...

متن کامل

Approaching Influence of Vehicle’s Properties in Crosswind and Overtaking Situations Using Multi-Step Taguchi Method

Most of drivers have to compensate small directional deviations from the desired driving path when disturbances such as crosswinds, overtakings, road irregularities and unintended driver inputs  are imposed. These types of deviations have a tiring effect on driver and traffic’s safety and should be minimised. To increase the understanding the influence of vehicle’s properties in crosswind and o...

متن کامل

A novel method for detecting structural damage based on data-driven and similarity-based techniques under environmental and operational changes

The applications of time series modeling and statistical similarity methods to structural health monitoring (SHM) provide promising and capable approaches to structural damage detection. The main aim of this article is to propose an efficient univariate similarity method named as Kullback similarity (KS) for identifying the location of damage and estimating the level of damage severity. An impr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2012