Histomorphometric evaluation of a threaded, sandblasted, acid-etched implant retrieved from a human lower jaw: a case report.
نویسندگان
چکیده
The purpose of this study was to histomorphometrically evaluate the bone-to-implant contact and bone area around a titanium implant retrieved from a human lower jaw. A screw-shaped titanium implant (sandblasted and acid-etched surface) was removed from a 68-year-old male after having been in function for 40 months because of a fracture of the abutment screw. Following the implant removal, an undecalcified section was obtained. The histomorphometric analysis showed a rate of 75.40% of bone-to-implant contact and 89.30% of bone area filling within the limits of the implant threads. The surrounding bone healed in a well-organized pattern and could not be differentiated from the original alveolus. The histologic evidence showed a high degree of osseointegration in a threaded, sandblasted, and acid-etched implant retrieved from a human lower jaw after functional loading for 40 months.
منابع مشابه
Histomorphometric evaluation of six dental implant surfaces after early loading in augmented human sinuses.
This study investigated the bone-to-implant contact (BIC) and osteoconductive capacity (OC) of 6 different implant surfaces after early loading in humans. Two implants with different surfaces were placed side-by-side in the grafted (n= 5) and nongrafted (n = 1) sinuses of 3 volunteers. Single-tooth restorations were delivered 60 days later. After 6 months of full occlusal loading, implants were...
متن کاملMachined and sandblasted human dental implants retrieved after 5 years: a histologic and histomorphometric analysis of three cases.
OBJECTIVE Human retrieved implants with an intact bone-implant interface play a pivotal role in validating data obtained from in vitro studies and animal experiments. This study presents a histologic and histomorphometric analysis of peri-implant tissue reactions and of the bone-titanium interface in three machined and sandblasted dental implants retrieved after a 5-year loading period. METHO...
متن کاملSurface analysis of machined versus sandblasted and acid-etched titanium implants.
Initially, implant surface analyses were performed on 10 machined implants and on 10 sandblasted and acid-etched implants. Subsequently, sandblasted and acid-etched implant cytotoxicity (using L929 mouse fibroblasts), morphologic differences between cells (osteoblast-like cells MG63) adhering to the machined implant surfaces, and cell anchorage to sandblasted and acid-etched implant surfaces we...
متن کاملThermal increment due to ErCr:YSGG and CO2 laser irradiation of different implant surfaces. A pilot study.
OBJECTIVE An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. STUDY DESIGN Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA) (impacted and threaded, respectively), a machined titanium surface implant (TI mach...
متن کاملEarly Bone Response to Dual Acid-Etched and Machined Dental Implants Placed in the Posterior Maxilla: A Histologic and Histomorphometric Human Study.
PURPOSE To compare the early bone response to implants with dual acid-etched (DAE) and machined (MA) surface, when placed in the posterior human maxilla. MATERIALS AND METHODS Fourteen patients received 2 implants in the posterior maxilla: 1 DAE and 1 MA. After 2 months, the implants were retrieved for histologic/histomorphometric evaluation. The bone-to-implant contact (BIC%), bone density i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Implant dentistry
دوره 14 3 شماره
صفحات -
تاریخ انتشار 2005