Detailed MR imaging anatomy of the cisternal segments of the glossopharyngeal, vagus, and spinal accessory nerves in the posterior fossa: the use of 3D balanced fast-field echo MR imaging.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The cisternal segments of the lower cranial nerves (CNs) adjacent to the jugular foramen (JF) are difficult to identify reliably by routine MR imaging. We performed a 3D balanced fast-field echo imaging technique (3D-bFFE) to obtain detailed anatomy of the cisternal segments of CNs IX, X, and XI. MATERIALS AND METHODS 3D-bFFE was used to image the cisternal segments of the lower CNs in 20 healthy volunteers. As an anatomic landmark, CSF recesses adjacent to the JF were divided into 3 parts: the recess for the cochlear aqueduct, the recess for CN IX, and the recess for the CN X/XI complex. MR images were evaluated to identify the cisternal segment of each cranial nerve in relation to these anatomic landmarks. RESULTS The mean angles of the recess for the cochlear aqueduct for CN IX and CN X/XI to the posterior petrous bone were 41.6 +/- 2.5 degrees , 69.7 +/- 3.1 degrees , and 76.0 +/- 3.4 degrees , respectively (P < .01). The mean length of the recess for the cochlear aqueduct for CN IX and the CN X/XI complex was 5.91 +/- 0.19, 5.08 +/- 0.11, and 4.76 +/- 0.13 cm, respectively (P < .01). 3D-bFFE adequately depicted the cisternal segments of CN IX on 38 sides (95%) and the CN X/XI complex on 39 sides (97.5%). CONCLUSIONS The cisternal segments of CN IX, CN X, and CN XI are well identified by using 3D-bFFE, especially by determining the angles of the CSF recesses adjacent to the JF.
منابع مشابه
Comparison of FSE T2W and 3D FIESTA sequences in the evaluation of posterior fossa cranial nerves with MR cisternography.
PURPOSE The aim of this study was to compare 3D fast imaging with steady state acquisition (3D FIESTA) to fast spin echo T2-weighted (FSE T2W) MRI sequences in the imaging of cisternal parts of cranial nerves V-XII. MATERIALS AND METHODS We retrospectively evaluated the temporal MRI sequences of 50 patients (F:M ratio, 27:23; mean age, 44.5 +/- 15.9 years) who were admitted to our hospital wi...
متن کاملEvaluation of jugular foramen nerves by using b-FFE, T2-weighted DRIVE, T2-weighted FSE and post-contrast T1-weighted MRI sequences.
PURPOSE To assess the most effective magnetic resonance imaging (MRI) sequence for the visualization of the 9th, 10th, and 11th cranial nerves (glossopharyngeal, vagus, and accessory nerves, respectively) in their intraforaminal/canalicular courses. MATERIALS AND METHODS Balanced fast-field echo (b-FFE), 3D-T2W DRIVE, T2W 2D TSE and post-contrast T1W MRI sequences were all applied and we trie...
متن کاملComparison Between Three-Dimensional Diffusion-Weighted PSIF Technique and Routine Imaging Sequences in Evaluation of Peripheral Nerves in Healthy People
Introduction: The present study aims to evaluate the Three-Dimensional Diffusion-Weighted reversed fast imaging with steady state free precession (3D DW-PSIF) sequence with respect to imaging of the peripheral nerves; the tibial, medial, and lateral plantar nerves in the lower extremity, ulnar and median nerve in the upper extremity, sciatic nerve, brachial plexus, and lumbosacral plexus, and a...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملThe jugular foramen: imaging strategy and detailed anatomy at 3T.
BACKGROUND AND PURPOSE The purpose of this study was to assess how well the anatomy of the jugular foramen (JF) could be displayed by 3T MR imaging by using a 3D contrast-enhanced fast imaging employing steady-state acquisition sequence (CE-FIESTA) and a 3D contrast-enhanced MR angiographic sequence (CE-MRA). MATERIALS AND METHODS Twenty-five patients free of skull base lesions were imaged on...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 30 6 شماره
صفحات -
تاریخ انتشار 2009