Controlled dynamic stability as the next step in “biologic plate osteosynthesis” - a pilot prospective observational cohort study in 34 patients with distal tibia fractures
نویسندگان
چکیده
INTRODUCTION Delayed bone healing is an eminent problem in the operative treatment of distal tibia fractures. To address this problem from a biomechanical perspective, the DLS 3.7 (Dynamic Locking Screw 3.7 mm) as a new generation of locking screws has been developed. This screw enables the surgeon to control the rigidity of the plate osteosynthesis and thereby to expand clinical options in cases where the bridge plating is chosen for fracture treatment. PURPOSE The purpose of the present prospective study was to evaluate the safety use of the DLS 3.7 in distal tibia fractures where bridge plating osteosynthesis is recommended. METHODS In a prospective non-controlled cohort study, 34 patients with acute distal tibia fractures (AO 43 A-C) were treated with an angular stable plate fixation using DLS 3.7 or LHS 3.5. Follow-up examinations were performed three, six, twelve, and twenty-four weeks postoperatively and all registered complications were carefully collected. RESULTS A total of 34 patients were prospectively enrolled in this study with a minimum follow-up of 6 months or obvious osseous consolidation at an earlier stage. No complications directly related to the DLS 3.7 were recorded and no infections were observed. CONCLUSIONS This observational study could show that the DLS 3.7 in combination with locking compression plates provides a secure and easy application. According to the recent literature inter-fragmentary micro-motion is one evident goal to increase the reliability in fracture healing. The new DLS 3.7 with a maximum micro-motion of 0.2 mm combines the advantage of micro-motion with the well-known advantages of angular stable plate fixation.
منابع مشابه
Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملEffectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures
Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...
متن کاملMinimally Invasive Plate Versus Intramedullary Interlocking Nailing In Distal Third Tibia Fractures
Prospective study of sixty patients with distal tibia fracture who underwent surgical fixation at Sri Ramachandra University between June 2010 -June 2013. Of the 60 patients included in our study 30 underwent closed intramedullary interlocking nail and 30 were treated with plate osteosynthesis (MIPO). Patients were followed up for clinical and radiological evaluation using modified Klernn and B...
متن کاملIntramedullary nailing and plate osteosynthesis for fractures of the distal metaphyseal tibia and fibula.
PURPOSE To assess the results of concurrent intramedullary nailing plus plate osteosynthesis for fractures of the distal tibia and fibula. METHODS 15 men and 10 women (mean age, 35 years) with concurrent fractures of the distal tibia and fibula underwent intramedullary nailing (for the tibia) and plate osteosynthesis (for the fibula). 17 fractures were type A1, 6 type A2, and 2 type A3. Compo...
متن کاملComparison of surgical management of extra-articular distal tibia fractures treated with closed intramedullary nailing and minimally invasive percutaneous plate osteosynthesis- a prospective study
Background: We compared the clinical, radiological and functional outcome of extra-articular distal tibia fractures treated with Minimal invasive plate osteosynthesis (MIPO) and intramedullary nailing (IMN) Methods: A prospective study included 51 patients (IMN-25 patients, MIPO-26 patients). Two groups were compared for mean operative time, mean hospital stay, mean healing time, complications,...
متن کامل