Determination of vancomycin and gentamicin clearance in an in vitro, closed loop dialysis system
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate the feasibility of utilizing an in-vitro, closed loop hemodialysis system as a method to assess drug clearance. Secondarily, this study tested the influence of variables (blood flow rate, dialysate flow rate, and type of filter) in the hemodialysis procedure on the clearance of vancomycin and gentamicin. METHODS An in-vitro, closed loop hemodialysis system was constructed. The vancomycin (30 mg/L) and gentamicin (25 mg/L) were added to a simulated blood system (SBS). Four conditions (C1-C4) were tested by defining the filter (Polyflux 170H or F180) and the blood and dialysate flow rates (BFR and DFR). All hemodialysis sessions were 3 hours in length and each condition was completed in duplicate. Dialysate effluent was collected in a 50 gallon polyethylene drum. Samples were collected (in duplicate) from the SBS and the dialysate effluent at baseline and at the end of the hemodialysis session. Samples were analyzed for vancomycin and gentamicin with an ultrahigh performance liquid chromatography/tandem mass spectrometry method. RESULTS A total of eight 3-hour hemodialysis sessions were conducted. For all tested conditions (C1-C4), vancomycin was undetectable in the SBS at the end of dialysis. However, total vancomycin recovery in the dialysis effluent was 85±18%, suggesting that up to 15% may have adsorbed to the dialysis filter or tubing. Gentamicin clearance from SBS was >98% in all tested conditions. Average gentamicin recovery in the dialysate effluent was 99±15%. CONCLUSION Both vancomycin and gentamicin were readily removed by high-flux hemodialysis under all conditions studied. No significant differences in drug clearance were observed between conditions used in this in vitro study. The clinical implications of changing these hemodialysis parameters are unknown.
منابع مشابه
A New Approach in Preliminary Design of Closed Loop Solar Thermal Systems (RESEARCH NOTE)
In this paper, a model for closed loop solar system is presented and an attempt is made to generalize the model to be utilized for primary design of any solar active thermal system. This model may be used for systems in which gas or a liquid are fluids that flow. Two new parameters, namely, the system heat delivery factor and the system heat absorption factor are introduced in the model. These ...
متن کاملLongitudinal hemodiafilter performance in modeled continuous renal replacement therapy.
BACKGROUND/AIMS With advanced anticoagulation, many institutions operate continuous renal replacement therapy (CRRT) circuits longer than manufacturers' recommendations. This extended use may change hemodiafilter performance and clearance properties. However, hemodiafilter performance over time has not been assessed. We investigated solute clearance over time in modeled CRRT. METHODS In vitro...
متن کاملFacility Location and Determination of the Transportation Routes in the Closed-loop Supply Chain Considering the Holding Cost
In recent years, the green supply chain has become a key strategy for the competitiveness of organizations, where the reverse and closed-loop supply chains are one way to achieve it. In the current competitive environment, the closed-loop supply chain helps reduce costs by re-using recyclables and reducing environmental pollution by reducing waste and extending product life. In this study, a cl...
متن کاملDistance protection closed-loop testing using RTDS
This paper presents a distance protection test procedure by applying the Real-Time Digital Simulator (RTDS) of a power system. RTDS is a tool to design, develop, and test power-system protection. The RTDS enables real-time computation of electromagnetic phenomena with a calculation time step of even 50μs. The hardware allows the import and export of many signals from the simulator to an ext...
متن کاملPharmacokinetics of gentamicin in patients undergoing continuous ambulatory peritoneal dialysis.
Teh pharmacokinetics of gentamicin were studied in seven chronic renal failure patients undergoing continuous ambulatory peritoneal dialysis. Patients received 100 mg of gentamicin in 2 liters of dialysate during an initial pass, and serum and dialysate samples were collected for gentamicin determination. Approximately 49% of the amount introduced into the peritoneal cavity was absorbed systemi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2014