Changes in measurement procedure from a radioassay to a microbiologic assay necessitate adjustment of serum and RBC folate concentrations in the U.S. population from the NHANES 1988-2010.

نویسندگان

  • Christine M Pfeiffer
  • Jeffery P Hughes
  • Ramon A Durazo-Arvizu
  • David A Lacher
  • Christopher T Sempos
  • Mindy Zhang
  • Elizabeth A Yetley
  • Clifford L Johnson
چکیده

The NHANES measured serum and RBC folate concentrations by using a radioassay during prefortification (1988-1994) and postfortification (1999-2006) periods followed by the use of a microbiologic assay (MBA) from 2007-2010. The MBA produces higher concentrations than does the radioassay and is considered to be more accurate. To allow for accurate long-term trending (1988-2010), we evaluated different regression models (linear, piecewise linear, and fractional polynomial) to assay-adjust the radioassay results to be comparable to the MBA results. The data used to derive the regression models originated from 2 crossover studies in which the 2 assays were applied to a set of 325 serum and 171 whole-blood samples. Fractional polynomial regression of logarithmically transformed data provided the best fit for serum folate. Linear regression of logarithmically transformed whole-blood data provided an equally good fit compared with the other models and was the simplest to apply for RBC folate. Prefortification serum and RBC folate geometric mean concentrations increased after adjustment from 13.0 to 16.7 nmol/L and from 403 to 747 nmol/L, respectively. Postfortification serum folate concentrations increased from ~30 to ~43 nmol/L, and RBC folate concentrations increased from ~600 to ~1100 nmol/L after adjustment, with some variation across survey cycles. The presented regression equations allow the estimation of more accurate prevalence estimates and long-term trends in blood folate concentrations in the U.S. population by using results that are equivalent to the MBA. This information will be useful to public health officials in the United States who are dealing with folic acid fortification issues.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of trends in serum and RBC folate in the U.S. population from pre- to postfortification using assay-adjusted data from the NHANES 1988-2010.

The NHANES has monitored folate status of the U.S. population from prefortification (1988-1994) to postfortification (1999-2010) by measuring serum and RBC folate concentrations. The Bio-Rad radioassay (BR) was used from 1988 to 2006, and the microbiologic assay (MBA) was used from 2007 to 2010. The MBA produces higher concentrations than the BR and is considered to be more accurate. Thus, to b...

متن کامل

Biomarkers of folate status in NHANES: a roundtable summary123456

A roundtable to discuss the measurement of folate status biomarkers in NHANES took place in July 2010. NHANES has measured serum folate since 1974 and red blood cell (RBC) folate since 1978 with the use of several different measurement procedures. Data on serum 5-methyltetrahydrofolate (5MTHF) and folic acid (FA) concentrations in persons aged ≥60 y are available in NHANES 1999-2002. The roundt...

متن کامل

Comparison of serum and red blood cell folate microbiologic assays for national population surveys.

Three laboratories participated with their laboratory-specific microbiologic growth assays (MA) in the NHANES 2007-2008 to assess whether the distributions of serum (n = 2645) and RBC folate (n = 2613) for the same one-third sample of participants were comparable among laboratories. Laboratory (L) 2 produced the highest and L1 the lowest serum and RBC folate geometric means (nmol/L) in the NHAN...

متن کامل

Serum 25-hydroxyvitamin D status of the US population: 1988-1994 compared with 2000-2004.

BACKGROUND Changes in serum 25-hydroxyvitamin D [25(OH)D] concentrations in the US population have not been described. OBJECTIVE We used data from the National Health and Nutrition Examination Surveys (NHANES) to compare serum 25(OH)D concentrations in the US population in 2000-2004 with those in 1988-1994 and to identify contributing factors. DESIGN Serum 25(OH)D was measured with a radioi...

متن کامل

Overview of a roundtable on NHANES monitoring of biomarkers of folate and vitamin B-12 status: measurement procedure issues123456

A roundtable dialogue to discuss "NHANES Monitoring of Biomarkers of Folate and Vitamin B-12 Status" took place in July 2010. This article provides an overview of the meeting and this supplement issue. Although the focus of the roundtable dialogue was on the measurement of folate and vitamin B-12 status biomarkers in NHANES, this article also describes the relevance and importance of these issu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of nutrition

دوره 142 5  شماره 

صفحات  -

تاریخ انتشار 2012