sEMG Interface Design for Locomotion Identification
نویسنده
چکیده
Surface electromyographic (sEMG) signal has the potential to identify the human activities and intention. This potential is further exploited to control the artificial limbs using the sEMG signal from residual limbs of amputees. The paper deals with the development of multichannel cost efficient sEMG signal interface for research application, along with evaluation of proposed class dependent statistical approach of the feature selection method. The sEMG signal acquisition interface was developed using ADS1298 of Texas Instruments, which is a front-end interface integrated circuit for ECG application. Further, the sEMG signal is recorded from two lower limb muscles for three locomotions namely: Plane Walk (PW), Stair Ascending (SA), Stair Descending (SD). A class dependent statistical approach is proposed for feature selection and also its performance is compared with 12 preexisting feature vectors. To make the study more extensive, performance of five different types of classifiers are compared. The outcome of the current piece of work proves the suitability of the proposed feature selection algorithm for locomotion recognition, as compared to other existing feature vectors. The SVM Classifier is found as the outperformed classifier among compared classifiers with an average recognition accuracy of 97.40%. Feature vector selection emerges as the most dominant factor affecting the classification performance as it holds 51.51% of the total variance in classification accuracy. The results demonstrate the potentials of the developed sEMG signal acquisition interface along with the proposed feature selection algorithm. Keywords—Classifiers, feature selection, locomotion, sEMG.
منابع مشابه
Application of statistical techniques and artificial neural network to estimate force from sEMG signals
This paper presents an application of design of experiments techniques to determine the optimized parameters of artificial neural network (ANN), which are used to estimate force from Electromyogram (sEMG) signals. The accuracy of ANN model is highly dependent on the network parameters settings. There are plenty of algorithms that are used to obtain the optimal ANN setting. However, to the best ...
متن کاملRecognition of Finger Motions for Myoelectric Prosthetic Hand via Surface EMG
Recently, myoelectric prosthetic arms/hands, in which arm/hand gesture is distinguished by the identification of the surface electromyogram (SEMG) and the artificial arms/hands are controlled based on the result of the identification, have been studied (Weir, 2003). The SEMG has attracted an attention of researchers as an interface signal of an electric actuated arm for many years, and many of ...
متن کاملSurface Electromyography: its Role and Potential in the Development of Exoskeleton (Review)
This study evaluates the effectiveness of superficial electromyography (sEMG) in the development of biocontrolled exoskeletons, through an analysis based on the findings of foreign and domestic literature on the subject. A brief historical background is provided. The features reviewed include the registration, processing and analysis of the signals from superficial electromyograms in respect of...
متن کاملEOG-sEMG Human Interface for Communication
The aim of this study is to present electrooculogram (EOG) and surface electromyogram (sEMG) signals that can be used as a human-computer interface. Establishing an efficient alternative channel for communication without overt speech and hand movements is important for increasing the quality of life for patients suffering from amyotrophic lateral sclerosis, muscular dystrophy, or other illnesse...
متن کاملA Wireless sEMG Recording System and Its Application to Muscle Fatigue Detection
Surface electromyography (sEMG) is an important measurement for monitoring exercise and fitness. Because if its high sampling frequency requirement, wireless transmission of sEMG data is a challenge. In this article a wireless sEMG measurement system with a sampling frequency of 2 KHz is developed based upon a MSP 430 microcontroller and Bluetooth transmission. Standard isotonic and isometric m...
متن کامل